Crestron Isys™ TPS-3000L 6.
This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names and trademarks are the property of their respective owners. ©2002 Crestron Electronics, Inc.
Crestron Isys™ TPS-3000L 6.4" Lectern/Wall Mounted Touchpanel Contents 6.4 Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ TPS-3000L 1 Introduction ............................................................................................................................... 1 Features and Functions ................................................................................................ 1 Specifications ..........................................................................................
Crestron Isys™ TPS-3000L 6.4" Lectern/Wall Mounted Touchpanel 6.4 Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ TPS-3000L Introduction Features and Functions The TPS-3000L series packs all the power and performance of an Isys panel in a stylish lectern or wall-mount model. Its compact stature makes the TPS-3000L series perfect for the home, especially in locations like home theaters, bedrooms and the home office. These touchpanels are available in three colors: almond, black, and white.
.4" Lectern/Wall Mounted Touchpanel Crestron Isys™ TPS-3000L TPS-3000L Functional Summary (Continued) • • • • • • • • • • • • Up to 4,000 Digital and Analog Signal Joins; Up to 999 Serial Signal Joins Built-in Microphone & 2 Speakers (Half Duplex Intercom Capable) Stores WAV Sound Files Automatic Light Sensor Capable of Inverting Image for optimum viewing whether mounting in a lectern or wall.
Crestron Isys™ TPS-3000L 6.4" Lectern/Wall Mounted Touchpanel Specifications The table below and on the next page provides a summary of specifications for the TPS-3000L touchpanel. Specifications for the TPS-3000L Touchpanel SPECIFICATION DETAILS Power Requirements 20 Watts (0.83 Amp @ 24 VDC) Default NET ID 03 Timeout Adjustable from 0 to 120 minutes (Default = 10 min.
6.4" Lectern/Wall Mounted Touchpanel Crestron Isys™ TPS-3000L Specifications for the TPS-3000L Touchpanel (Continued) SPECIFICATION Video DETAILS • Composite/S-Video input through 6-position mini-phoenix (Balanced 100 Ω: cable run not to exceed 500 feet (152.4 meters)), or BNC (Unbalanced 75 Ω: cable run not to exceed 100 feet (30.5 meters)).
Crestron Isys™ TPS-3000L 4. 6.4" Lectern/Wall Mounted Touchpanel Extension requires a prefix specific to the touchpanel type. In DETAILS, projectname represents the assigned project name, and xxxxxx represents a version number. NOTE: Crestron software and any files on the website are for Authorized Crestron dealers only. New users may be required to register to obtain access to certain areas of the site (including the FTP site). Physical Description The 6.4 inch (16.
6.4" Lectern/Wall Mounted Touchpanel Crestron Isys™ TPS-3000L Physical Views of the TPS-3000L Touchpanel (Top, Front, and Side) 8.60 in (21.84 cm) 8.45 in (21.46 cm) 2.81 in (7.29 cm) 2.67 in (6.78 cm) 2.30 in (5.84 cm) 9.36 in (23.77 cm) 7.65 in (19.43 cm) 6.57 in (16.69 cm) 0.40 in (1.00 cm) 0.32 in (0.81 cm) Physical View of the TPS-3000L Touchpanel (Back) 8.05 in (20.45 cm) 7.00 in (17.79 cm) 6 • 6.4 Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ TPS-3000L Operations Guide – DOC.
Crestron Isys™ TPS-3000L 6.4" Lectern/Wall Mounted Touchpanel Industry Compliance As of the date of manufacture, the touchpanel have been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling (N11785). NOTE: This device complies with part 15 of the FCC rules.
6.4" Lectern/Wall Mounted Touchpanel Crestron Isys™ TPS-3000L NOTE: All network wiring must consist of two twisted pairs. One twisted pair is the +24V conductor and the GND conductor. The other twisted pair is the Y and Z conductors. NOTE: When daisy-chaining Cresnet units, strip the ends of the wires carefully to avoid nicking the conductors. Twist together the ends of the wires that share a pin on the network connector, and tin the twisted connection. Apply solder only to the ends of the twisted wires.
Crestron Isys™ TPS-3000L 6.4" Lectern/Wall Mounted Touchpanel Lectern Mounting If the touchpanel is to be installed into a lectern, the touchpanel must be set to the “Inverted” configuration. The “Inverted” configuration provides optimum viewing when installed into a lectern.
6.4" Lectern/Wall Mounted Touchpanel 4. Crestron Isys™ TPS-3000L Lift and turn over the pushbutton circuit board to view the cable connecting the circuit board to the touchpanel. Refer to the following diagram. Pushbutton Circuit Board (Bottom View) J2 Screw Holes J1 Ribbon Cable 5. Release the tension clip on the ZIF connector (labeled J1) by gently sliding the clip approximately 1/16” toward the pushbutton circuit board edge and remove the ribbon cable from the connector.
Crestron Isys™ TPS-3000L 6.4" Lectern/Wall Mounted Touchpanel Remove the Ribbon Cable 6. Rotate the pushbutton circuit board 180º and slide the ribbon cable into the open connector (labeled J2). Insert the cable with the leads facing away from the pushbutton circuit board. 7. Secure the ribbon cable by gently sliding the tension clip toward the connector body. 8. Turn over the circuit board in its new orientation and install the two pushbutton circuit board screws to finger-tight.
6.4" Lectern/Wall Mounted Touchpanel MAIN MENU Crestron Isys™ TPS-3000L To configure the unit, it may be necessary to access a series of setup screens prior to viewing run-time screens that are loaded into the touchpanel for normal operation. The MAIN MENU for configuring the touchpanel appears when a finger is held to the touchscreen as power is applied. Remove your finger when the message “SETUP MODE” appears on the touchscreen.
Crestron Isys™ TPS-3000L 6.4" Lectern/Wall Mounted Touchpanel Interface Menu INTERFACE MENU The touchpanel communicates with a control system to activate commands or to display feedback from components within the system. The communication interface must be correctly specified or communication will not occur. To set communication parameters select the Interface button located on the SETUP MENU and display the INTERFACE MENU, shown to the left.
6.4" Lectern/Wall Mounted Touchpanel Crestron Isys™ TPS-3000L Audio Setup Details (continued) AUDIO MENU BUTTON AUDIO SETUP SCREEN Line 88% (On) Line Enable line level audio with the Line On button. Line Off disables this feature. Adjust the volume with the UP and DOWN buttons. All Audio (On) All Audio Control All types of audio may be disabled with a single button press. All Audio Off activates global muting. All Audio On enables all audio. Key Click Enabled (Vol.
Crestron Isys™ TPS-3000L 6.4" Lectern/Wall Mounted Touchpanel Video Setup Details (continued) VIDEO SCREEN BUTTONS1 DESCRIPTION2 Saturation UP button increases video image saturation, DOWN button decreases video image saturation. Hue UP button increases video image hue, DOWN button decreases video image hue. Still/Motion (toggle) The Motion setting eliminates motion artifacts caused by the difference between the first and second halves of a video field and softens the image.
6.4" Lectern/Wall Mounted Touchpanel SCREEN SETTINGS BRIGHTNESS SCREEN SETTINGS – AUTO BRIGHTNESS THRESHOLD Crestron Isys™ TPS-3000L BRIGHTNESS Press the Brightness button to open the SCREEN SETTINGS – BRIGHTNESS display. Manual controls are located on the left side and automatic controls are located on the right side. Two buttons, ENABLE and DISABLE, are used to determine whether the touchpanel brightness is controlled manually or automatically via thresholds.
Crestron Isys™ TPS-3000L 6.4" Lectern/Wall Mounted Touchpanel RS-232 Menu RS-232 MENU The touchpanel allows for four RS-232 communication methods: • Console (i.e. loading programs) • Control (i.e. non-Crestron device) • Touch output (communication of touch coordinates to an external device) • External touch screen input. Touch the communication option to select communication parameters and then select Save and Return to save the RS-232 settings and return to the SETUP MENU.
6.4" Lectern/Wall Mounted Touchpanel Crestron Isys™ TPS-3000L Hardware Connections for the TPS-3000L (Back of the Unit is Shown) CONNECTS TO CONTROL SYSTEM FOR RS-232 COMMUNICATION CONNECTS TO AUDIO SOURCE CONNECTS TO VIDEO SOURCE CONNECTS TO MICROPHONE RS-232 This 6-position RJ11 connector mates with a serial port of a PC. The connecting cable is not supplied.
Crestron Isys™ TPS-3000L 6.4" Lectern/Wall Mounted Touchpanel PC to TPS-3000L Cable Specifications (Crestron Cable Number STCP-502PC) NET This 4-position mini-phoenix connector provides Cresnet network connection from the touchpanel as well as power to the touchpanel. A description of the pinouts is shown in the table after this paragraph.
6.4" Lectern/Wall Mounted Touchpanel Crestron Isys™ TPS-3000L NOTE: When sending balanced audio from a CNX-BIPAD8 or CNX-PVID device, only the Positive (+) and Negative (-) wires are to be connected to the touchpanel. Do not connect the Shield (S) wires.
Crestron Isys™ TPS-3000L 6.4" Lectern/Wall Mounted Touchpanel NTSC/PAL Balanced Video Input Pinouts (continued) PIN # DESIGNATION DESCRIPTION 4 C(+) Chrominance (Positive) 5 C(-) Chrominance (Negative) 6 C(S) Chrominance (Shield) NOTE: When sending balanced video from a CNX-BIPAD8 or CNX-PVID device, only the Positive (+) and Negative (-) wires are to be connected to the touchpanel. Do not connect the Shield (S) wires.
6.4" Lectern/Wall Mounted Touchpanel Crestron Isys™ TPS-3000L 3. Insert the touchpanel (without its faceplate) into the mounting option and align the four screw holes. 4. Insert and tighten the four supplied screws (finger tight and then using a #1 Phillips screwdriver, tighten an additional 1/8-turn). 5. Insert the five buttons. If the buttons are engraved, verify that the placement of the each button matches the programming. 6. Cover the mounted unit with the faceplate.
Crestron Isys™ TPS-3000L 6.4" Lectern/Wall Mounted Touchpanel 1. Lift the plastic cover off the touchpanel. Do not apply excessive pressure to the touchscreen. 2. Remove the plastic buttons from the touchpanel. If the buttons are engraved, be sure to record the button engraving with the button location so that the buttons can be properly returned. 3. Loosen and remove the four screws that secure touchpanel to the mounting option in use. 4.
6.4" Lectern/Wall Mounted Touchpanel Crestron Isys™ TPS-3000L • SIMPL Windows version 2.02.11 or later with library update file. Requires SIMPL+ Cross Compiler version 1.1. • Crestron Database version 15.8.6 or later. Required by SIMPL Windows. • VisionTools Pro-e version 2.4.1.6 or later. Used for graphical touchscreen design. • Crestron Engraver 2.0.0.9 or later. NOTE: The TPS-3000L touchpanel is supplied with five blank pushbuttons.
Crestron Isys™ TPS-3000L 6.4" Lectern/Wall Mounted Touchpanel Configuration Manager is where programmers “build” a Crestron control system by selecting hardware from the Device Library. In Configuration Manager, drag the PRO2 from the Control Systems folder of the Device Library and drop it in the upper pane of the System Views. The PRO2 with its associated communication ports is displayed in the System Views upper pane. PRO2 System View The System Views lower pane displays the PRO2 system tree.
6.4" Lectern/Wall Mounted Touchpanel Crestron Isys™ TPS-3000L Setting the Net ID in Device Settings Double-click the TPS-3000 icon to open the “Device Settings” window. This window displays the TPS-3000 device information. If necessary, select the Net ID tab to change the Net ID, as shown in the following figure.
Crestron Isys™ TPS-3000L 6.4" Lectern/Wall Mounted Touchpanel Signal Types Signals interconnect the various devices and logic symbols that comprise a SIMPL program. Signals can be one of three types: digital, analog, or serial. For any given signal, the signal type is determined by its driving source. That is, if the symbol that drives the signal has an analog output, then, by definition, the connecting signal is analog.
6.4" Lectern/Wall Mounted Touchpanel Crestron Isys™ TPS-3000L selects the signal types by clicking on the appropriate button at the top of the Symbol Detail view when programming the panel. The following tables list and give functional descriptions for the touchpanel outputs and inputs. Digital Output Signal Descriptions OUTPUT DESCRIPTION press 1 through press 4000 Notifies control system of button press (1 - 4000).
Crestron Isys™ TPS-3000L 6.4" Lectern/Wall Mounted Touchpanel two and three-dimensional buttons, sliders, and digital readouts which allow the user to interface with the control system via join numbers. Unjoined objects are not interfaced with the system and thus cannot initiate any functions. The completed and compiled project is uploaded to the touchpanel and programmed into the flash PROM via the File | Upload Project command.
6.4" Lectern/Wall Mounted Touchpanel Crestron Isys™ TPS-3000L panel designer has the option to suppress the keyclick on a button-by-button basis from the “Button Properties” window. Crestron VT Pro-e (version 2.1.0 and later) contains an audio tool, Sound Manager, which permits the panel designer to attach WAV files to a touchpanel project. Sound Manager is available from the Tools pull-down menu and opens the “Sound Manager” window, shown after this paragraph.
Crestron Isys™ TPS-3000L 6.4" Lectern/Wall Mounted Touchpanel b. Mute Sounds – All WAV files (except the keyclick) in the project are muted when this join number goes high. c. Mute Key Click – The keyclick sound is muted when this join number goes high. Using Sound Manager Sound Manager is broken into two distinct components. The Project Audio Joins component, shown below, permits the designer to assign the three system-wide join numbers described in the previous section.
6.4" Lectern/Wall Mounted Touchpanel Crestron Isys™ TPS-3000L The Properties button opens the “Sound Properties” window for a highlighted WAV file in the Sound List table. The designer can assign a join number either automatically with the Auto button or by scrolling down to the desired number. Select Description to enter comments about the WAV file. “Quick” Pushbuttons The touchpanel includes five “quick” pushbuttons, located on the side of the LCD screen.
Crestron Isys™ TPS-3000L 6.
6.
Crestron Isys™ TPS-3000L 6.
6.4" Lectern/Wall Mounted Touchpanel Crestron Isys™ TPS-3000L MultiByte International Characters Most languages use a single byte of 8 bits to represent a character, e.g. English, French, German, Hebrew, Russian, Thai, etc. Multibyte character fonts require more than the usual 8 bits to specify a character. This occurs when a language has more than 256 characters (28) in a font. For example, Chinese fonts contain several thousand characters. Other multibyte languages include Japanese and Korean.
Crestron Isys™ TPS-3000L 6.4" Lectern/Wall Mounted Touchpanel Communication Settings Connection of a PC to the TPS-3000L touchpanel can be direct via the RS-232 port on the touchpanel or through a control system (Cresnet). Both methods of connection provide setup for RS-232 communication. To prepare the TPS-3000L for uploading or upgrading, refer to the following figure for a typical connection diagram.
6.4" Lectern/Wall Mounted Touchpanel Crestron Isys™ TPS-3000L Setup | Communications Settings Command 4. Select RS-232 as the connection type. Verify that an available COM port (COM 1 is shown after this step) is selected, and that all communication parameters and necessary options from the “Port Settings” window are selected as shown after this step. Click the OK button to save the settings and close the window.
Crestron Isys™ TPS-3000L 6.4" Lectern/Wall Mounted Touchpanel NOTE: If connecting to the touchpanel through a control system, the baud rate may need to be set to 38400 baud (Cresnet speed) for a successful transfer. NOTE: If connecting to a touchpanel through a control system, control system communications can be verified by selecting Diagnostics | Establish Communications (Find Rack). This should display a window that gives the COM port and baud rate.
6.4" Lectern/Wall Mounted Touchpanel Crestron Isys™ TPS-3000L “Send Program” Window 4. To verify that the program has been transferred successfully, select Diagnostics | Report Program Information or press F7. This should display a window that provides details about the current program loaded into the control system. Uploading a VT Pro-e Project The TPS-3000L touchpanel source file has the extension .vtp. A compiled VT Pro-e file has the extension .vtz.
Crestron Isys™ TPS-3000L 6.4" Lectern/Wall Mounted Touchpanel File Transfer | Send Touchpanel Command 3. As shown after this step, select the NET ID of the TPS-3000L touchpanel and then click OK. The “Touch Panel Transfer” window appears (refer to the subsequent graphic). “Select Network ID” Window Check Send Direct to Wired Touchpanel if connected via RS-232 directly to touchpanel.
6.4" Lectern/Wall Mounted Touchpanel 4. Crestron Isys™ TPS-3000L Click Browse. The “Open” window appears as shown in the following illustration. “Open” Window 5. Select the VT Pro-e (vtz) file and click Open. The transfer will complete automatically. Firmware Upgrade A firmware upgrade file has the extension .csf. To take advantage of all the TPS-3000L features, it is important that the unit contains the latest firmware available. Therefore, please check the Crestron website (http://www.crestron.
Crestron Isys™ TPS-3000L 6.4" Lectern/Wall Mounted Touchpanel “Select Network ID” Window Check Send Direct to Wired Touchpanel if connected via RS-232 directly to touchpanel. Select CSF File 4. Operations Guide – DOC. 6077 Browse to the .csf file and click Open to begin the transfer. 6.
6.4" Lectern/Wall Mounted Touchpanel Crestron Isys™ TPS-3000L Problem Solving Troubleshooting The table after this paragraph provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. TPS-3000L Touchpanel Troubleshooting TROUBLE POSSIBLE CAUSE(S) Touchpanel does not function. Touchpanel is not communicating with the network. Use Performance Viewport (via SIMPL Windows or VT Pro-e) to poll the network.
Crestron Isys™ TPS-3000L 6.4" Lectern/Wall Mounted Touchpanel Further Inquiries If after reviewing this Operations Guide, you cannot locate specific information or have questions, please take advantage of the Crestron award winning customer service team by calling: • In the US and Canada, call the Crestron corporate headquarters at 1-888-CRESTRON [1-888-273-7876]. • In Europe, call Crestron International at +32-15-50-99-50. • In Asia, call Crestron Asia at +852-2341-2016.
6.4" Lectern/Wall Mounted Touchpanel Crestron Isys™ TPS-3000L Appendix: RS-232 Protocol TPS-3000L touchpanels support panel operation via a host computer through the RS-232 port. Crestron recommends that the following serial data format is set. Suggested Serial Data Format Baud Rate: 38400 Data Bits: 8 Parity: None Stop Bits: 1 These settings may be altered via the RS-232 Menu when configuring the touchpanel, however, doing so may prevent Crestron supplied software from operating with the touchpanel.
Crestron Isys™ TPS-3000L 6.4" Lectern/Wall Mounted Touchpanel information received from the touchpanel (i.e., jumping pins 2 and 3 on the RS-232 port) makes the buttons momentary. Notice that the touchpanel responds to P and R commands even when configured for other interface modes. Selecting an RS-232 interface mode merely enables P and R commands to be issued. In addition, the fixed format is not required for commands sent to the touchpanel; P1, P01, and P001 are all perfectly valid commands.
6.4" Lectern/Wall Mounted Touchpanel Crestron Isys™ TPS-3000L Software License Agreement This License Agreement (“Agreement”) is a legal contract between you (either an individual or a single business entity) and Crestron Electronics, Inc. (“Crestron”) for software referenced in this guide, which includes computer software and, as applicable, associated media, printed materials, and “online” or electronic documentation (the “Software”).
Crestron Isys™ TPS-3000L 6.4" Lectern/Wall Mounted Touchpanel If You are a business or organization, You agree that upon request from Crestron or its authorized agent, You will within thirty (30) days fully document and certify that use of any and all Software at the time of the request is in conformity with Your valid licenses from Crestron of its authorized agent.
6.4" Lectern/Wall Mounted Touchpanel Crestron Isys™ TPS-3000L Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange, or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact the factory and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying the nature of the problem, name and phone number of contact person, RMA number, and return address. 2.
Crestron Isys™ TPS-3000L 6.4" Lectern/Wall Mounted Touchpanel This page intentionally left blank. Operations Guide – DOC. 6077 6.
Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576 www.crestron.com Operations Guide – DOC. 6077 12.02 Specifications subject to change without notice.