Leading Specifications of the TPS- XTXRF (continued)
SPECIFICATION DETAILS
Operating Ranges (line of sight)
Minimum Distance
3 ft
2
Maximum Distance Indoor
150 ft
2
Maximum Distance Outdoor
1000
ft
Operating Temperature
Approximately +32
o
to +104
o
F (0
o
to 40
o
C)
Charging Temperature
Approximately +50
o
to +95
o
F (10
o
to 35
o
C)
Storage Temperature
Approximately -4
o
to +113
o
F (-20
o
to 45
o
C)
SIMPL™ Windows®
Version 2.00.28 or later
3
Crestron Database
Version 15.7.3 or later
3
Isys
TM
Touchpanel Firmware
Version 1.012.0 or later
4 & 5
2-Series Control System Update File
6
Version C2-1008.CUZ or later
7 & 8
2 The location of the TPS-RFGWX and the orientation of the antenna are important
factors in the RF performance. With the unit located outside of any metal enclosures,
the antenna is adjusted to achieve the best range. The range is dependent on its
placement and the building in which it is used. The construction of the building,
obstructions and RF interference from other devices are factors determining the
effective range of the unit. To prevent unit-to-unit RF interference, multiple
gateway/transceivers operating at the same frequencies (TPS-RFGWXs and/or Crestron
CNRFGWXs) should not be installed within 3-5 feet of each other.
NOTE: Implementing multiple gateways (TPS-RFGWXs) to extend the range is not
permitted (i.e., no roaming).
3 The latest software version can be obtained from the Downloads | Software Updates
section of the Crestron website (www.crestron.com
). Refer to NOTE after last footnote
on page 5.
4 The TPS-RFGWX and touchpanels with later versions of firmware may include features
not mentioned in this guide. Newer versions of this guide can be obtained from the
Downloads | Product Manuals section of the Crestron website (www.crestron.com
).
5 The firmware upgrade files can be obtained from the Downloads | Software Updates
section of the Crestron website. Refer to NOTE after last footnote on page 5.
Crestron recommends that the latest firmware be loaded into the TPS-RFGWX and
associated touchpanel(s). When the firmware is upgraded, the touchpanel(s) firmware
must be upgraded at the same time.
6 Crestron 2-Series control systems consist of the AV2, AV2 with Card Cage, CP2,
CP2E, PAC2, PRO2, and RACK2
7 Filenames for 2-Series control system update files have a CUZ extension and can be
obtained from the Downloads | Software Updates section of the Crestron website
(www.crestron.com
). New users are required to register in order to obtain access to the
FTP site.
8 When loading VT Pro-e files or firmware through the RS-232 port of the control
system, be sure that the baud rate is 57600 or lower. Otherwise, the Viewport may post
the “Transfer Failed” message. Higher baud rates (i.e., 115,000) can be selected, but
hardware handshaking (RTS/CTS) must be used.
4 Two-Way RF Transceiver Module: TPS-XTXRF Operations & Installation Guide - DOC. 5844