Installation Instructions

Installation Instructions
For #BG 082 L.P. Gas Conversion Kit
Converting 16,000 BTU/hr Gas Burners from Natural Gas to
Liquefied Petroleum (Bottled Gas)
Parts included in Kit:
1 Instruction Sheet
1 Blocking Pin
1 Orifice, Burner-Propane No.56
1 Label, Rating Plate Conversion (English)
1 Label, Rating Plate Conversion (French)
1 Label, Conversion Record (English)
1 Label, Conversion Record (French)
1 Label, Burner Baseplate (English /French)
NOTE: This instruction sheet contains information for converting two different
design gas valves. Read instructions thoroughly and follow steps.
Warning: This conversion kit shall be installed by a qualified service agency in
accordance with the manufacturer's instructions and all applicable codes and
requirements of the Authority Having Jurisdiction. The information in these instructions
must be followed to minimize the risk of fire or explosion or to prevent property damage,
personal injury, or death. The qualified service agency is responsible for the proper
installation of this kit. The installation is not proper and complete until the operation of the
converted appliance is checked as specified in the manufacturer's instructions supplied
with the kit.
NOTE: A qualified service technician is any person or representative of a company who is
experienced or trained in servicing gas equipment and is familiar with necessary
precautions,
Canada Only
THIS CONVERSION KIT SHALL BE CARRIED OUT IN ACCORDANCE WITH THE
REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN
ACCORDANCE WITH THE REQUIREMENTS OF THE CAN-B49.1 AND CAN1-B149.2
INSTALLATION CODE.
NOTE: Read these instructions before proceeding.
IMPORTANT: The LP Conversion Kit you received is an approved kit for converting your
gas dryer from natural to LP propane gas.
This dryer has been manufactured for use with Natural gas. Installation of this conversion
kit converts the dryer for use with L.P. gas with manifold pressure of 11” water column and
supply pressure between 8” and 13” water column. If this dryer is converted for use with
L.P. gas by means of this kit, the input rating will be 16,000 BTU's per hour. The
instructions are to address derating at altitudes above 2000 feet; e.g., clothes dryer input
ratings are based on sea level operation and need not be changed for operation up to 2000
feet elevation. For operation at elevations above 2000 feet, input ratings should be
reduced at the rate of 4 percent for each 1000 feet above sea level.