Product Manual

Crommelins Generator Operation & Instruction Manual
5. OVERLOAD PROTECTION
5.1 NON-TRADE PACK MODELS
These generators are protected by an overload button positioned on the end cover of alternator next
to the power outlets.
In the event of overloading the generator, the overload protection button will trip and will cut the
power output from the generator set and the engine will continue to run.
Switch off the connected appliances and unplug them from the power outlets.
Check the individual and combined appliances compliance plates for wattage draw, they must not
exceed that of the generator. Push the overload button in to reset it.
5.2 TRADE PACK MODELS
These generators are protected by an RCD device which protects against earth current faults, overload,
and short circuits. This is located in a weatherproof enclosure next to the weatherproof outlets.
This device will trip in the event of either of these being detected and cut the power output from the
generator, the engine will continue to run.
Switch off the connected appliances and unplug them from the power outlets. Check the individual
appliances compliance plates for wattage draw and for any damage to the power cable or appliance.
Reset the switch on the RCD upwards to regain power. If the RCD trips again cease using the appliance
immediately.
NOTE: The RCD device must be tested every time the generator is started and before any appliances
are plugged in.
6. OPERATING PROCEDURES
6.1 STARTING THE GENERATOR
󱛻󱛼󱛽CAUTION
ALWAYS unplug all appliances connected to generator before starting.
Check the oil level before each operation as outlined by the section “CHECK ENGINE OIL”.
KEEP all bystanders at a safe distance from the generator and work areas.
Children and animals MUST always be kept away from the generator and work areas.
STEP 1 Turn the engine switch to the position ‘I’ (On).
STEP 2 Open the fuel valve.
STEP 3 Set choke lever to close if the engine is cold.
Recoil Start:
o Pull the starter handle slowly until passing the compression point (resistance will be felt), then
return the handle to its original position and pull briskly.
o If the engine fails to start after several attempts, repeat above procedures with choke lever
returned to “OPEN” position.
o Do not fully pull out the rope.
o After starting, allow the starter handle to return to its original position while still holding the
handle.