LEAK TESTING OPERATION
WARNING: DO NOT USE AN OPEN FLAME.
LEAK TESTING: This must be done before initial use, annually, and whenever any gas
components are replaced or serviced. Do not smoke while performing this test, and remove
all sources of ignition. See leak testing diagram for areas to check. Turn all burner controls to
the off position. Turn gas supply valve on. Brush a half-and-half solution of liquid soap and
water onto all joints and connections of the regulator, hose, manifolds and valves. Bubbles
will indicate a gas leak. Either tighten the loose joint or have the part replaced with one
recommended by your manufacture and have the appliance inspected by a certified gas
installer.
If the leak cannot be stopped, immediately shut off the gas supply, disconnect it, and have the
appliance inspected by a certified gas installer. Do not use the appliance until the leaks have
been corrected.
WARNING: A leak test must be performed annually or if a part of the gas system is
replaced.
WARNING: Never use an open flame to check for gas leaks. Be certain no sparks
or open flames are in the area while you check for leaks. Sparks or open flames will result
in a fire or explosion, damage to property, serious bodily injury, or death.