Instructions / Assembly

You must provide propane gas and propane cylinder. Use a standard 20 lb. propane
cylinder only.
Use this heater only with a propane vapor withdrawal supply system. See Chapter 5 of
the Standard for Storage and Handling of Liquefied Petroleum Gas, ANS/NFPA 58. Your
local library or fire department should have this book.
The pressure regulator and hose assembly supplied with the appliance must be used.
The installation must conform with local codes, or in absence of local codes, with National
Fuel Gas Code, ANSI Z223.1.
A dented, rusted, or damaged propane cylinder may be hazardous and should be checked
by your cylinder supplier. Never use a propane cylinder with a damaged valve connection.
The LP-gas supply cylinder must be constructed and marked in accordance with the
U.S. Department of Transportation (D.O.T) Specifications for LP-Gas Cylinders, or the
standard for Cylinders, Spheres and Tubes for Transportation of Dangerous Good and
Commission, CAN/CSA-B339, as applicable.
The LP-gas supply cylinder must be provided with a cylinder connection device
compatible with the connection for the appliance.
The cylinder used must include a collar to protect
the cylinder valve.
The LP-gas supply cylinder must be provided
with a listed overfill protection device (OPD).
Do not store a spare LP gas cylinder under or
near this appliance.
Never fill the cylinder beyond 80 percent full.
For appliances designed to use a CGA No.
791IQCC connection.
Place the dust cap on the cylinder valve outlet
whenever the cylinder is not in use.
Note: Gas supply pressure: 25 PSI to 250 PSI.
4
WARNING: FUELS USED IN LIQUIFIED PROPANE GAS APPLIANCES, AND THE
PRODUCTS OF COMBUSTION OF SUCH FUELS, CAN EXPOSE YOU TO
CHEMICALS INCLUDING BENZENE, WHICH IS KNOWN TO THE STATE OF
CALIFORNIA TO CAUSE CANCER AND CAUSE BIRTH DEFECTS OR OTHER
REPRODUCTIVE HARM. For more information go to: www.P65Warnings.ca.gov.
Standard 20 lbs. tank