Installation guide

Electrical
Requirements
VENTING
A
WARNING
Venting
Requirements
Be
bells
6
Electrical
Shock
Hazard
Plug
into
a
grounded
3
prong
outlet.
Fire
Hazard
Do
not
remove
ground
prong.
Use
a
heavy
metal
vent
Do
not
use
an
adapter.
Do
not
use
a
plastic
vent.
Do
not
use
an
extension
cord.
Do
not
use
a
metal
foil
vent.
Failure
to
follow
these instructions
can
result
in
death,
. .
Failure
to
follow
these
instructions
can
result
in
death
fire,
or
electrical
shock.
or
fire.
@
120
Volt,
60
Hz.,
AC
only,
15-
or
20-amp fused
electrical
. . .
supply
is
required.
A
time-delay
fuse
or
circuit
breaker
is
WARNING:
To
reduce
the
risk
of
fire,
this
dryer
MUST
BE
recommended.
It
is
also
recommended
that
a
separate
EXHAUSTED OUTDOORS.
circuit
serving
only
this
dryer
be
provided.
IMPORTANT:
Observe
all
governing
codes
and
ordinances.
Dryer
exhaust
must
not
be
connected
into
any gas
vent,
GROUNDING
INSTRUCTIONS
chimney,
wall,
ceiling,
attic,
crawlspace,
or
a
concealed
space
of
a
building.
Only
rigid
or
flexible
metal
vent
shall
be
used
for
@
For
a
grounded,
cord-connected
dryer:
exhausting.
This
dryer
must
be
grounded.
In
the
event
of
malfunction
or
breakdown,
grounding
will
reduce
the
risk
of
electric
shock
by
providing
a
path
of
least
resistance
for
electric
current.
\
This
dryer
is
equipped
with
a
cord
having
an
equipment-
(102
mm)
grounding
conductor
and
a
grounding
plug.
The
plug
must
be
plugged
into
an
appropriate
outlet
that
is
properly
installed
and
grounded
in
accordance
with
all
local
codes
and
ordinances.
4"
(102
mm)
heavy
metal
exhaust
vent
@
Only
a4"
(102
mm)
heavy
metal
exhaust
vent
and
clamps
may
be
used.
@
Donotuse
plastic
or
metal
foil
vent.
WARNING:
improper
connection
of
the
equipment-
grounding
conductor
can
result
in
a
risk
of
electric
shock.
Check
with
a
qualified
electrician
or
service
representative
or
personnel
if
you
are
in
doubt
as
to
whether
the
dryer
is
Rigid
metal
vent:
properly
grounded.
Do
not
modify
the
plug
provided
with
m&
Recommended
for
best
drying
performance
and
to
avoid
the
dryer:
if
it
will
not
fit
the
outlet,
have
a
proper
outlet
crushing
and
kinking.
installed
by
a
qualified
electrician.
Flexible
metal
vent:
(Acceptable
only
if
accessible
to
clean)
SAVE
THESE
INSTRUCTIONS
@
Must
be
fully
extended
and
supported
in
final
dryer
location.
@
Remove
excess
to
avoid
sagging
and
kinking
that
may
result
in
reduced
airflow
and
poor
performance.
@
Do
not
install
in
enclosed
walls,
ceilings,
or
floors.
@
The
total
length
should
not
exceed
7°/s
ft.
(2.4
m).
NOTE:
If
using
an
existing
vent
system,
clean
lint
from
entire
length
of
the
system
and
make
sure
exhaust
hood
is
not
plugged
with
lint.
Replace
plastic
or
metal
foil
vents
with
rigid
metal
or
flexible
metal
vents.
Review
“Vent
System
Chart”
and,
if
necessary,
modify
existing
vent
system
to
achieve
best
drying
performance.