Service Manual
PAGE 15-F
FUNCTION OF PELL INDICATOR
1. Pell Indicator mounted on left side of Barrel at Front End of Breech Block (400-12) indicates when Pellet is in
Chamber. Location of Breech Block (400-12) on Barrel (400-2) is controlled with Indicator Housing (400-30). Indicator Set
Screw (400-33) must be tight.
FEED ARM:
1. Feed Arm (400-10) must be tight on Cam (400-9) and lined up to work freely in slot milled in Breech Block. 2 Feed
Arm Set Screws are provided for locking Feed Arm to Cam.
2. Feed Sleeve (400-8) must fit freely on Cam (400-9) and Breech Bolt (400-3) must fit freely in Breech Block (400-
12) and line up with hole in Feed Arm (400-10).
MAGAZINE ASSEMBLY:
TO REMOVE:
1. Magazine Assembly (400-15) from Breech Block (400-12) turn slot down and pull to rear.
2. To insert Magazine Assembly into Breech Block Hold Slot Down Push Forward until Ball clicks into groove. Turn
Magazine to Right until slot side shows.