2.5.5 Gain/Level Changes
When you get to this menu note that the gain changes will be made as you make them but if you do not wish to
save the changes you have made, scroll to “R” and push the menu/Execute switch and select “NO” in the
“SAVE SETTINGS?” window or do not press the Menu/Execute switch; simply do nothing for
approximately 12 seconds, and the system will return to the normal operating mode.
2.5.5.1 Upconverter Input Level
To set the upconverter input level, first push the Menu/Execute switch until you get to the upconverter input
level setting:
Operate the Menu/Execute switch until you get to the menu item you want to change see Figure 2.4
for the sequence of menu options.
The following display is for changing the upconverter input level. This is an important setting to
optimize spurious and should be made as accurately as possible:
UP INLVL = -20
R
Pressing the Up/Down switch down will toggle the display digit selected until you have the desired
level. NOTE: THE VALUE WILL NOT BE STORED UNTIL YOU INDICATE YES IN THE
SAVE SETTINGS WINDOW.
UP INLVL = -10
R
By using the horizontal rocker switch the cursor can be moved left or right .
UP INLVL = -10
R
When the display indicates the value desired you can push the Menu/Execute switch to the next item
OR you can scroll to “R”, push the Menu/Execute switch to get to:
SAVE SETTINGS?
Y N
Selecting Y will save the new settings. Selecting N will revert to the previous settings.
Pushing the Menu/Execute switch then takes you to the :
U F=1450 G=+00.0
D F=1350 G=+20.0
Figure 2.4 shows all the menu items and how to make changes.
2017-03A Manual, Rev. H Page 18 10/08/13