Instruction manual

C) Status Requests -
Table 1.2 lists the status requests for the 2016-03A and briefly describes them.
* PLEASE NOTE: The two character {aa}(00-31) prefix, in the table below,
should be used ONLY when R
S-485, (OPTION-Q), is selected.
TABLE 1.1 2016-03A Status
Requests
TABLE 1.1 2016-03A Status Requests
Command Syntax* Description
Command Status {aaS1} Returns {S1bbbbccIA} where:
• bbbb = Rx frequency
4 characters - standard (7 characters - Option-X)
• cc = Rx gain
• I = 1 - spectrum invert enabled
• A = summary alarm; 1=alarmed, 0=normal
10MHz Ref Status {aaS2} Returns {S2ER} where:
(option -E only)
• E = 1 - external 10 MHz switched in
• R = 1 - 10 MHz ref inserted on RF input connector
LNB Current {aaS3} Returns {S3eee} where:
(option -L only)
• eee = LNB current (000 to 500 = 0 to .500 A)
2016-03A Manual, Rev A Page 6 11/25/08