SDS
M A T E R I A L S A F E T Y D A T A S H E E T
Page: 1
CROSSCRETE
11/21/2011
PRODUCT NAME: CROSSCRETE HMIS CODES: H F R P
PRODUCT CODE: AM013 3 0 0 C
================== SECTION I - MANUFACTURER IDENTIFICATION =================
MANUFACTURER'S NAME: MAX CHEMICAL INC
ADDRESS : PO BOX 363841
SAN JUAN PR 00936-3841
EMERGENCY PHONE : DATE PRINTED : 11/21/2011
INFORMATION PHONE : 787-765-6100 NAME OF PREPARER : MAX CHEMICAL, INC
========== SECTION II - HAZARDOUS INGREDIENTS/SARA III INFORMATION =========
VAPOR PRESSURE
REPORTABLE COMPONENTS CAS NUMBER mm Hg @ TEMP % WT
------------------------------------------------------------------------------------------------------------------------------------
* Hydrogen Chloride 7647-01-0 78 mmHg 20 C 49.83
HCl OSHA CLV 5PPM; 7MG/M3
ACGIH CLV 2PPM
PHOSPHORIC ACID 007664-38-2 0.03MMHG 20C 14.61
NONYLPHENOL ETHOXYLATE 9016-45-9 <0.075 .83
TWA OEL SHORT TERM OE-RL:PPMA, MG/M3B, PPMA, MG/M3B
BLEND MIXTURE N/D N/D .17
COMPLEX SUBSTITUTED KETO-AMINE/ 143106-84-7/ 50-60%
HYDROCHLORIC ACID/ 07647-01-0/ 0-3%
ISOPROPYL ALCOHOL/ 00067-63-0/ 1-10%
PROPARGYL ALCOHOL/ 00107-19-7/ 1-10%
+ Indicates a product that is considered hazardous material under the OSHA Hazardous Comunication Standard ( 29 CFR
1910.1200).
* Indicates Toxic Chemical(s) subject to reporting requirements of section 313 of Title III of CFR 372.
=============== SECTION III - PHYSICAL/CHEMICAL CHARACTERISTICS ============
BOILING RANGE: 150-230 F - 158C SPECIFIC GRAVITY (H2O=1): 1.16
VAPOR DENSITY: 1.27 (Air=1) EVAPORATION RATE: (Butyl Acetate=1)
<1.00
COATING V.O.C.: 9.16 lb/gl MATERIAL V.O.C.: 0.01 lb/gl
SOLUBILITY IN WATER: SOLUBLE
APPEARANCE AND ODOR: CLEAR, COLORLESS LIQUID WITH PUNGENT, IRRITATING ODOR.
================= SECTION IV - FIRE AND EXPLOSION HAZARD DATA ==============
FLASH POINT: 20C METHOD USED: TCC
FLAMMABLE LIMITS IN AIR BY VOLUME- LOWER: n/a UPPER: n/a
EXTINGUISHING MEDIA: Nonflammable, use agent suitable for surrounding fire
SPECIAL FIREFIGHTING PROCEDURES
Approach fire from upwind to avoid hazardous vapors. Use flooding quantities of water as fog or spray to keep fire-
exposed containers cool. Extinguish fire using agent suitable for surrounding fire.
Firefighters should wear chemical protective suit with self contained positive-pressure breathing apparatus.