UV Pure Technologies Inc. ULT RAVI O L ET WAT ER PURI F I CAT IO N SYST EM INSTRUCTION MANUAL MODEL: Hallett 15xs VOLTAGE: SERIAL #: NSF/ANSI 55 CLASS A CERTIFIED Certified to IEC PUBLICATION 60335.
Hallett 15xs Instruction Manual INSTRUCTION MANUAL Copyright UV Pure Technologies Inc. 2012 All rights reserved. No part of this document may be photocopied, reproduced, transmitted, or translated to another language without the prior written consent of UV Pure Technologies Inc. UV Pure®, Hallett®, and Crossfire Technology® are registered trademarks of UV Pure Technologies Inc.
Hallett 15xs Instruction Manual 1. ABOUT THE HALLETT The Upstream and the Hallett systems, manufactured by UV Pure Technologies, are the world’s only ultraviolet water purification device with patented Crossfire Technology. Patented in US 6,707,048, Canada 2,463,503, Australia 2,002,333,084, Mexico 248805 Patent Pending in Japan, UK, Europe, & Eurasia UV Pure’s Hallett UV systems employ revolutionary Crossfire Technology that is self-cleaning, self-monitoring, and fail-safe.
Hallett 15xs Instruction Manual The Hallett 15xs has a smart display: The operator interface is designed to allow unprecedented access to information such as lamp lifetime, message history and UV intensity display. The Hallett 15xs can show remote status: Be alerted to any change in system status immediately in any room with the optional Remote Monitor. The monitor is a handheld wireless device that can be placed in a convenient location to provide operational information about the Hallett.
Hallett 15xs Instruction Manual 1. ABOUT THE HALLETT .................................................................................... 3 2. INSTALLATION INSTRUCTIONS ......................................................................... 6 Before Beginning Installation ................................................................. 6 Water Conditions - Pre-treatment Parameters ........................................ 6 Safety Information...............................................................
Hallett 15xs Instruction Manual 2. INSTALLATION INSTRUCTIONS Before Beginning Installation Water Conditions - Pre-treatment Parameters Note this section is designed to ensure the optimal performance of your Hallett system. Please review the following pre-treatment parameters prior to installation. If any specifications are of concern or unclear please contact your water treatment dealer or specialist.
Hallett 15xs Instruction Manual prevent damage (see Draining Instructions page 31). The water temperature range is 1–40°C (34–104°F). In extreme conditions with both low air and water temperatures, a Thermal Abatement Kit R400074 may be necessary. Energy Requirements: There are two standard operating voltages for the Hallett 15xs unit. The unit may be 115Vac or 100-240 Vac and draws 175W. Please refer to the power input label located near the power cord entry of the unit. See Figure 1B.
Hallett 15xs Instruction Manual External dry contact for remote monitoring or optional autodialer. 20’ of flexible hose for connection of purge valve to drain Transient Voltage Surge Suppressor (TVSS)/Surge Protective Device (SPD) for North American markets (120Vac systems) Optional - Pre-treatment sediment and or carbon filter designed to remove water particles, odor or trace chemicals for improved taste.
Hallett 15xs Instruction Manual clearances. The Hallett is intended only for indoor use in a dry location. Should these minimum installation recommendations not be met, the system will not operate effectively. The Hallett should be installed downstream of (after) any pre-treatment devices such as filters, water softeners etc and also any pressure tanks.
Hallett 15xs Instruction Manual 9.0" [228mm] 7.54" [191mm] 23.75" [603mm] CLEARANCE REQ'D. TO REMOVE WIPER 25" [635mm] 3.49" WATER OUT 1" MNPT [89mm] OPEN Hallett 28.27" [718mm] 35.76" [908mm] NSF/ANSI 5 5 CL ASS A CERTIFIED CERTIFIEN SF/ANSI 5 5 CL ASSE A NSF/ANSI 5 5 CL ASSE A CERTIFICADO uv pure.com 1 WATER IN 1" MNPT TO MOUNT USE #12 OR 4" DIA. SCREW (4-PLACES) 3.5" [89] 12.0" [305] Figure 1A Released on 20-Sept-12 – H800003P Page 10 UV Pure Technologies Inc.
Hallett 15xs Instruction Manual Connecting the Pipes We recommend that a qualified plumber or certified technician perform the water connections for your Hallett. Water must flow into the inlet at the bottom of the unit. The outlet is located at the top of the unit. Install the shutoff valve before the unit. Step 1: Shut off the water supply. Caution: Always turn off the water supply before modifying or disconnecting any piping.
OPTIONAL DRAIN VALVE MANUAL SHUTOFF VALVE SOLENOID VALVE (UNI-DIRECTIONAL) (TEST VALVE MONTHLY) FLEXIBLE HOSE POWER CORD ENTRY & LOCATION OF SERIAL NUMBER GROUNDED OUTLET 115VAC 50/60Hz OR 100-240VAC 50/60Hz PURGE VALVE (SEE FIG.
FL O W Released on 20-Sept-12 – H800003P F LO AUTOMATIC PO SITION Page 13 MANUAL SHUTOFF VALVE ON /RE SET SOLENOID VALVE (UNI-DIRECTIONAL) (TEST VALVE MONTHLY) POW ER FLEXIBLE HOSE TRANSIENT VOLTAGE SUPPRESSOR OFF SUPPLIED FOR NORTH AMERICAN MARKETS ONLY GROUNDED OUTLET 115VAC 50/60Hz OR 100-240VAC 50/60Hz POWER CORD ENTRY & LOCATION OF S/N HALLETT UNIT MOUNTED VERTICAL AGAINST A WALL FLEXIBLE HOSE DRAIN PURGE VALVE DISCHARGE LINE PURGE VALVE RELOCATED BETWEEN OPTIONAL SOLENOID VALVE AND
Hallett 15xs Instruction Manual MOUNT UNIT FLAT AGAINST A BOARD OR SHIM OR INCORRECT CORRECT Figure 1E Caution: Do not connect the unit to electrical power until the piping and unit are free of water leaks. The solenoid valve can be placed into manual mode to allow water to enter the unit. Switch back to automatic mode when done.
Hallett 15xs Instruction Manual chamber to prevent damage to internal components. TYPICAL INSTALLATION OF PARALLEL UNITS MANUAL SHUTOFF VALVE - ESSENTIAL CHECK VALVE ESSENTIAL SOLENOID VALVE 20" FILTER HOUSING OPTIONAL DRAIN MANUAL SHUTOFF VALVE - ESSENTIAL Figure 1F Step 2: Plug the female end of the power cord into the power entry module located on the left side of the front panel. The power cord must be removed before front panel can be opened. See Figure 1B or 1C.
Hallett 15xs Instruction Manual Voltage Surge Suppressor into a grounded electrical outlet. Flip the switch on the Transient Voltage Surge Suppressor to ON position. Installation is now complete. Important: after the unit has been operating for a few hours, unplug the unit and check all hose connections for leaks (the top hose in particular). Repeat this procedure periodically. Proceed to system operation for further instruction to ensure optimal performance.
Hallett 15xs Instruction Manual each unit in parallel or series.) Each Hallett within an approximate 500 feet, line of sight, range should have a different bind number. Once you have chosen a bind number press Enter. Leave menu display at “Remote Device Bind #” Step 2: Pick up the remote monitor and then connect the battery. The remote will display “Init…, Version # of program and then “UNBOUND” (if never initially bound).
Hallett 15xs Instruction Manual The door to the ballast enclosure must be opened to gain access to external alarm and remote start/stop contacts. As well, the blower and blower housing must be removed for cable entry. See Figure 1G & 1H. Step 1: Loosen screw that secures door – no need to remove. Step 2: Unplug blower from circuit board – connector J6. Step 3: Open blower housing panel and remove screw that secures it. Step 4: Gently pull out blower housing and blower allowing connector and wire to follow.
Hallett 15xs Instruction Manual CIRCUIT BOARD LOOSEN SCREW TO OPEN BALLAST ENCLOSURE DOOR (DO NOT REMOVE) VIE W A TILT FORWARD THEN REMOVE SCREW AIR FILTER KNOCKOUT LOCATED BLOWER HOUSING PANEL FLIPS DOWNWARD Figure 1H BLOWER HOUSING PANEL PLUG TO J6 BLOWER CLIPS TO LATCH TO METAL HOUSING Figure 1I Released on 20-Sept-12 – H800003P Page 19 UV Pure Technologies Inc.
Hallett 15xs Instruction Manual 3. OPERATING INSTRUCTIONS The Hallett applies advanced Crossfire Technology, yet is simple to operate. The automatic quartz cleaning technology has been designed to reduce, and in most cases, eliminate the periodic shutdowns necessary to inspect the cleanliness of the quartz.
Hallett 15xs Instruction Manual full power or the unit is in standby mode awaiting a remote start. Amber Light – situated in the middle, an illuminated amber light may indicate the Initial Set-up process has begun or a warning of some condition that, if not addressed, could impact the Hallett’s performance. Warnings should be addressed as soon as possible. Warnings are accompanied with a single beep, messages and troubleshooting tips on the LCD display.
Hallett 15xs Instruction Manual complete, a solid green light appears and the message “Unit Treating” will be displayed. The solenoid valve will be allowed to open during the Initial Set-up process. This is the normal operating mode of the unit. During normal operation if a power outage occurs, the unit will start up within a few minutes and an alarm will occur if the unit is not treating within 10 minutes. If the UV lamps fail to ignite, the unit will try several more times before issuing an alarm.
Hallett 15xs Instruction Manual worldwide. However power spikes, surges and brownouts are a common occurrence in all countries. When that happens, line voltages may fluctuate outside the systems’ operating specifications. Installation of the supplied TVSS/SPD between the UV system and the power source will increase the ability of the system to survive transient events on the AC power.
Hallett 15xs Instruction Manual Step 1: Turn off the unit by unplugging it. Step 2: Shut off the water supply and relieve the water pressure by opening a faucet. Step 3: Remove the filter from its housing and fill the housing with bleach. Step 4: Re-mount the housing (but not the filter) and plug in the Hallett to turn it on.
Hallett 15xs Instruction Manual screen by pressing LEFT arrow several times. Next press RIGHT arrow to silence the audio alarm and review which alarm condition exists. The menu will bring you to Alarms and Troubleshooting section for assistance with current condition. The Message History can be reviewed to examine other recent events. Note that the audible alarm can be silenced for 24 hrs, 48 hrs, 1 week or permanently in the Service Section of the menu.
Hallett 15xs Instruction Manual M AIN M ENU When a unit is new or the UV lamps have been replaced and the Lifetime counter has been reset, the system begins an Initial Setup process which may last 24hrs. Continue to operate unit. Self Diagnostics INITIAL SET-UP MAY TAKE 24HRS..
Hallett 15xs Instruction Manual SERVICE M ENU Service Menu Enable Wiper AUTO Enable Wiper AUTO/ON/OFF Enable Purge Valve AUTO Enable Purge Valve AUTO/ON/OFF Shutoff Valve AUTO Shutoff Valve AUTO/ON/OFF Temperature Readings Water Temp. deg C deg F Enabling/Disabling Valve is temporary. Items return to AUTO mode after 10 minutes. UV Air Temp. deg C deg F CB Air Temp. deg C deg F The Audio Alarm or beeper, can be temporarily or permanently disabled.
Hallett 15xs Instruction Manual SETUP M ENU Setup Menu Hallett 15xs Language English English/French Remote StartStop Disabled Remote StartStop Disable/Enable Shutoff Valve Installed Not Installed / Installed Unit Configuration Enter Password ###### Language Shutoff Valve Remote Device BIND # Bind Remote Device Remote Device BOUND ALARMS & TROUBLESHOOTING M ENU This column represents all possible reasons for the fault.
Hallett 15xs Instruction Manual ALARMS & TROUBLESHOOTING M ENU (CONT’D) This column represents all possible reasons for the fault.
Hallett 15xs Instruction Manual M ESSAGE HISTORY M ENU Message History Alarm, Warning or Status messages Last 50 messages Message # Time #### hrs Time based on lamp counter 5. M AINTENANCE Test Shutoff Valve Monthly The Optional Solenoid Shutoff valve should be tested monthly to confirm it opens and closes. Unplug valve from unit to confirm water stops flowing. Plug the valve in again to confirm water continues to flow.
Hallett 15xs Instruction Manual Tools Needed Slotted screwdriver NOTE: Resetting the Lamp Lifetime counter will clear the Message History, Lamp Starts counter and Power Ups counter. If this information is required, review it first before proceeding to Step 1. NOTE: DO NOT TWIST/TURN THE LAMPS WHILE PINS ARE ENGAGED UV www.uvpure.
Hallett 15xs Instruction Manual Step 1: From the Main Menu, scroll down (push bottom arrow) to Lamp life remaining screen. Press Enter to move to next screen to reset counter. Press Enter again and then push Up or Down key to select YES and then press Enter. The lamp hours will reset to 9000 and the unit will turn off the lamps automatically. This will close the solenoid valve and temporarily shut off the water supply. Unplug power cord from left hand side of unit.
Hallett 15xs Instruction Manual Step 2: Shutdown and unplug the unit from the electrical outlet. Step 3: Place a bucket under the unit to collect the water. Step 4: Open a faucet downstream of the unit. Step 5: If you have installed the optional drain valve, open the drain valve. If you do not have an optional drain valve, disconnect the Stainless flexible hose below the unit and allow the system to drain for a few minutes.
Hallett 15xs Instruction Manual the quartz sleeve with any tool, since even the smallest chip can cause it to break under pressure. PULL OUTWARDS AND LIFT REMOVE TOP COVER LOOSEN WING NUT QUARTZ Figure 4A In-place cleaning Your Hallett is equipped with a self cleaning wiper that (in normal operating circumstances) maintains the quartz, and is engineered to ensure years of full disinfection. However, there are rare instances where water chemistry requires some manual quartz cleaning as well.
Hallett 15xs Instruction Manual 8 17 2 13 14B 1 7 17 5 3 4 12 17 6 11 16 10 16 17 18 19 Flow Restrictor 15 14A 13 9 20 8 17 Figure 4B – Hallett Released on 20-Sept-12 – H800003P Page 35 UV Pure Technologies Inc.
Hallett 15xs Instruction Manual Hallett 15xs Spare Parts List Item No.
Hallett 15xs Instruction Manual screwdriver (counterclockwise while looking at the shaft). DISCONNECT FLEX. HOSE REMOVE WIPER ASSY. BY ROTATING IT COUNTERCLOCKWISE AS YOU LIFT REMOVE & SUPPORT TOP QUARTZ SEAL ASSEMBLY DISCONNECT 1/4" PURGE VALVE DRAIN CUT WIRE TIE WRAP WHEN NECESSARY MOTOR MOTOR PURGE VALVE PURGE VALVE THERMISTOR THERMISTOR WIRES Figure 4C Step 8: Drain the unit and inspect the quartz sleeve. If clean, flush the unit with clean water. If fouling remains, repeat procedure.
Hallett 15xs Instruction Manual shaft of the wiper assembly (12). Handle these parts with care to prevent water leaks. REMOVE TOP O-RING REMOVE & SUPPORT TOP QUARTZ SEAL ASSEMBLY LIFT QUARTZ SLEEVE OUT OF THE UNIT REMOVE BOTTOM O-RING REMOVE BOTTOM QUARTZ SEAL ASSY. DISCONNECT FLEX. HOSE REMOVE COVER: PULL OUTWARDS AND DOWN Figure 4D Use the 7/16” (11mm) wrench to remove the four nuts in an alternating pattern (top left, bottom right, bottom left, then top right).
Hallett 15xs Instruction Manual Cleaning/Removing the Quartz Sleeve Note that numbers in parentheses refer to Figure 4B. Step 1: Use a bottle cleaning brush with a long handle to scrub the inside of the quartz sleeve. Scrub and flush it with water repeatedly to clean the quartz. Use a squeeze bottle to apply water or solution to the quartz sleeve to keep the area tidy. Note: Keep the rest of the unit free from moisture. Examine the quartz.
Hallett 15xs Instruction Manual Step 3: Tighten the nuts in an alternating pattern. Bundle the wires if necessary. Step 4: Reconnect the flexible hoses (8), both top and bottom. Close the front panel. Step 5: Close any faucets and open the water supply. Inspect for leaks. The solenoid valve (optional) can be placed into manual mode to allow water to enter the unit. Switch back to automatic mode when done. Repair any leaks if necessary.
Hallett 15xs Instruction Manual Dealer Name: Model: Serial Number (located on the left side of the front panel below power cord entry): 6. SERVICE RECORD SHEET Record lamp replacement dates and events in the space provided below. Date Action (MMM/DD/YYYY) System Installed 7. UV PURE TECHNOLOGIES LIMITED WARRANTY Limited Warranty for UV Pure Technologies’® water purification systems and peripheral parts purchased in Canada, the United States, Australia and New Zealand.
Hallett 15xs Instruction Manual One-year Limited Warranty for lamps, sensor probes, solenoid valves, and remote lamp replacement reminder alarm. Specifically this includes the following Parts: UV lamps, UV sensors and the circuit board they are mounted in, temperature probes, solenoid and purge valves, and the remote lamp replacement reminder alarm. Ninety-day Limited Warranty or Balance of Original Warranty for replacement Parts or Products.
Hallett 15xs Instruction Manual USE OF REPLACEMENT UV LAMPS THAT ARE NOT ORIGINAL UV PURE EQUIPMENT WILL INVALIDATE CERTIFICATION TO OR BY NSF, MENV, EPA, AND OTHER VALIDATION PROTOCOLS AND CERTIFYING BODIES. All UV lamps lose power over their usable lifetime; original equipment UV Pure lamps are engineered and tested to ensure that all of our systems achieve the minimum power for disinfection specified, at the end of lamp life.
Hallett 15xs Instruction Manual limited to repair or replacement of the defective Part or Product and this liability shall terminate upon the expiration of the applicable warranty period as set out above. This Limited Warranty may be amended or changed at any time, at UV Pure’s sole discretion, without notice. UV Pure offers inspection and refurbishing for older systems.