The door to the ballast enclosure must be opened to gain access to external 
alarm and remote start/stop contacts. As well, the blower and blower housing 
must be removed for cable entry. See Figure 1G & 1H. 
Step 1: Loosen screw that secures door – no need to remove. 
Step 2: Unplug blower from circuit board – connector J6. 
Step 3: Open blower housing panel and remove screw that secures it. 
Step 4: Gently pull out blower housing and blower allowing connector and wire to 
follow. 
Step 5: Remove knockout & install conduit / external wiring up to circuit board 
and terminate. Wiring may be secured internally to standoffs but allow enough 
slack to allow front panel to open. 
Step 6: Test opening of front panel to ensure newly installed wires do not restrict 
movement. 
Step 7: Replace blower and blower housing and allow connector & wire back to 
the circuit board. Secure with screw. Ensure wires do not obstruct blower. 
Step 8: Plug in blower connector to J6. 
Step 9: Close ballast enclosure door and secure with screw. 
(SEE FIGURE 1H)
GROUND
POWER INPUT
MOTOR, P. VALVE
UV BLOWER
AIR THERMISTOR
CB FAN
REMOTE S/S 0 (+)
REMOTE S/S 1 (-)
DRY CONTACT NC
GROUND
NET UVT 4-20mA+
NET UVT 4-20mA-
DRY CONTACT NO
DRY CONTACT COMM
RS485 B
RS485 A
UVI 4-20mA-
UVI 4-20mA+
ISO-485 PWR-
ISO-485 PWR+
& W. THERMISTOR
BLUE
YELLOW
RED
YELLOW
SHUTOFF VALVE 
TB1
J2
J6 J14 J7
TB3D
TB3C
TB3B
TB3A
J1
F1
(MARKED RED)
SHUTOFF (INTERLOCK)
SWITCH BEHIND PCB
CIRCUIT BOARD (PCB)
VIEW WITH BALLAST ENCLOSURE DOOR OPEN
UNPLUG UNIT BEFORE OPENING DOOR
DO NOT REPLACE
FUSE IF IT BLOWS.
A BLOWN FUSE
IMPLIES MAJOR PCB
FAULT. REPLACE
ENTIRE PCB.
F1
J1
TB3A
TB3B
TB3C
TB3D
J7J14J6
J2
TB1
SHUTOFF VALVE 
YELLOW
RED
YELLOW
BLUE
& W. THERMISTOR
ISO-485 PWR+
ISO-485 PWR-
UVI 4-20mA+
UVI 4-20mA-
RS485 A
RS485 B
DRY CONTACT COMM
DRY CONTACT NO
NET UVT 4-20mA-
NET UVT 4-20mA+
GROUND
DRY CONTACT NC
REMOTE S/S 1
REMOTE S/S 0
CB FAN
AIR THERMISTOR
UV BLOWER
MOTOR, P. VALVE
POWER INPUT
GROUND
Figure 1G