Instruction manual
Hallett 15xs Instruction Manual 
Released on 20-Sept-12 – H800003P  Page 36  UV Pure Technologies Inc. © 2012 
Hallett 15xs Spare Parts List 
Item 
No. 
Hallett 
15xs 
Qty  Part Name
1  E300210
1  Lamps (shipped in pairs- Single lamp p/n E300209)
2  H400000  1  Purge Valve Repair Kit
3 
H400001 / 
H400006 
1  115V Circuit Board / 100-240V Circuit Board* 
4  H400002
1  UV Sensor Array Replacement Kit
5  H400003  1 
Top SS Manifold/Thermistor/Purge Valve 
Replacement, 1” 
6  H400008  1  Cabinet Door For Hallett 15xs 
7  R400005
1  Wiper Motor Kit
8  R400007  2  1" Flexible SS Hose 
9  R400008  1  Reactor Cooling Blower Kit (including filter) 
10  R400009  1  Fan Filter 
11  R400010
1  Quartz sleeve Replacement Kit (includes 2 O rings)
12  R400011  1  Wiper Assembly Kit 
13  R400017  2  Top or Bottom Cap 
14A  R400018  1  Air Thermistor Replacement Kit 
14B  R400044  1  Water Thermistor Replacement Kit 
15  R400019  1  Circuit Board Cooling Fan Replacement Kit 
16  R400026  1  Reflector Kit (shipped & sold in pairs) 
17  R400031  1  Seal Kit (complete) 
18  R400033
1  Lamp Socket Wire Harness
19  R400047  1  Bottom SS Manifold, 1”
20 
E500021 / 
E500021U 
1 
Solenoid shut-off Valve for 120V systems / 240V 
systems (Note that coil is 24Vac in both cases) 
21  R400054  1 
Remote Monitor Kit - (Contains handheld & 
Transmitter) 
22  R400030  1  Remote Monitor (Handheld unit only) 
23  150207  1 
Transient Voltage Surge Suppressor for 115V 
systems 
Figure 4B – Parts List 
*Do not replace the fuse in the unit if it blows. A blown fuse indicates major circuit 
board fault. Replace entire circuit board. Inspect lamps-replace if discolored. 
Step 4: Disconnect the top hose from the plumbing side (not the unit side but 
other end). 
Step 5: Add about 2 oz. (60cc) of cleaning solution to the top hose. The cleaning 
solution can be a citric acid, vinegar or other non-hazardous solutions. Any 
solution used should be thoroughly rinsed out afterwards. Fill the rest of the 
quartz with water. 
Step 6: Let the cleaning solution remain in the quartz for at least 10-20 minutes. 
Step 7: Manually turning the wiper may greatly assist the cleaning process. To 
do this, remove the motor assembly and turn the wiper shaft with a flat-bladed 