Instruction manual
Hallett 15xs Instruction Manual 
Released on 20-Sept-12 – H800003P  Page 9  UV Pure Technologies Inc. © 2012 
clearances. 
The Hallett is intended only for indoor use in a dry location. Should these 
minimum installation recommendations not be met, the system will not operate 
effectively. 
The Hallett should be installed downstream of (after) any pre-treatment devices 
such as filters, water softeners etc and also any pressure tanks. However, it must 
be installed upstream of (before) any branches in the piping so that all the 
water is disinfected before splitting and distributing throughout the home or 
facility. If the plumbing system has a grounding lug or strap, this should also be 
upstream from the unit, shutoff valve or filters. If grounding of the Hallett or 
plumbing system is in question, please consult your local electrical inspector. 
Time Required 
Please note that full installation of the Hallett requires shutting off the main water 
supply for a number of hours. If disinfection is necessary, all pipes must be 
treated and flushed. Once the unit is plugged in, the new UV lamps may take 
from a few moments to several hours to reach full power. Having a Lamp Alarm 
is normal with a new system (or with newly installed lamps) until the lamps have 
reached full power. 
Summary of Installation: 
Unpack and install Hallett on wall 
Install top & bottom hose to unit and to plumbing 
Install Shutoff solenoid valve 
Install optional bypass & drain plumbing 
Install purge valve discharge line to a suitable drain line 
Connect system power cord to the Transient Voltage Surge Suppressor 
Connect Transient Voltage Surge Suppressor to grounded power outlet 
Assembling the Unit 
Step 1: Unpack the unit, being careful to remove all packaging material. Inspect 
the unit for damage particularly the quartz sleeve – See Figure 4A for 
disassembly. Check if UV lamps fully inserted. Check & tighten the nuts securing 
the top and bottom stainless manifolds - see Figure 4B. 
Step 2: The Hallett has four keyhole slots for convenient mounting – all four 
should be used. Do not mount the unit directly to an outside wall; mount on 
plywood or shims – See Figure 1E. Do not install the unit horizontally. 
Remove the top and bottom covers of the unit to make the mounting holes 
accessible. 
Step 3: Connect the Stainless flexible hoses to both the top and bottom of the 
Hallett. Make sure that the sealing washer is inside the hose end before making 
the connection. Tighten securely. Wrap the top hose with pipe insulation. (Not 
provided) 