Instruction manual
Hallett 13 & 30 Instruction Manual - Wastewater & Reuse
Released on 1-May-14 – XH115B Page 17 UV Pure Technologies Inc. © 2014
3. OPERATING INSTRUCTIONS
The Hallett applies advanced Crossfire Technology, yet is simple to operate.
With automatic quartz cleaning, periodic shutdowns are not necessary to inspect
the cleanliness of the quartz. The only required maintenance is the replacement
of the two UV lamps every 12 months (note - if you shut your system down for
seasonal use - the lamp life will be extended)
Unit Functions
HOURGLASS
WATER NOT CLEAN
LAMP
FAUCET AND GLASS
RESET BUTTON
RESET LAMP TIMER
RED LIGHT
WATER QUALITY FAULT
RED LIGHT
LAMP FAULT
GREEN LIGHT
UNIT TREATING
Figure 2
There are three indicating lights and a pushbutton on the front panel.
See Figure 2.
At the top beside the FAUCET AND GLASS graphic is a green light that,
when illuminated, indicates the unit is safe or treating normally.
In the middle beside the LAMP graphic is a red light that, when illuminated,
indicates a lamp fault.
Near the bottom beside the WATER NOT CLEAN graphic is a red light that,
when illuminated, indicates a water quality fault.
At the very bottom under the "Hourglass" graphic is a reset button that you
will use after replacing lamps (see Lamp Replacement section for more
detail.) Pressing the button also silences the audible alarm for 24 hours.
Although the audible alarm is off, the red light for the specific alarm will
remain illuminated and the solenoid valve will remain closed. Unplugging
and plugging in the unit will re-enable the audible alarm.
See Troubleshooting Guide for description of faults.
Starting the Unit
Caution: Avoid continuously starting and stopping the unit within a 24 hr period,
as this will accelerate the aging of the UV lamps (note: however shutting down
the system for seasonal use will extend lamp life).
Caution: Do not operate unit dry. There must be water in the treatment
chamber to prevent damage to internal components. In the event of a lack of
water, unplug the unit until the water supply can be restored. In the event of a
power failure, the unit will shut down and the optional solenoid valve will close,
Display Pad
p/n E100016