Instruction manual

Hallett 13 & 30 Instruction Manual - Wastewater & Reuse
Released on 1-May-14 – XH115B Page 25 UV Pure Technologies Inc. © 2014
Step 2: Loosen the screws and remove the top and bottom covers.
Step 3: Remove the lamps (see Replacing UV Lamps). Keep the lamps in a safe
place.
LOOSEN SCREWS
HALLETT 13 HALLETT 30
Figure 4A
Step 4: Remove the side cover panels by loosening the two screws on the top
fold. On the Hallett 13, the reflector is attached to the cover panel – see Figure
4A. On the Hallett 30, the reflectors are held in place by a U-clip and pins. First
remove the U-clip from both sides, the remove the back reflector by gently
pushing the tab out from the alignment pins. To remove the front reflector, the UV
sensor can be removed. If the left lamp is removed, the front reflector can be
manipulated out leaving UV sensor in place.
Step 5: Examine the quartz sleeve both inside and out. If it is clean, no
disassembly is required. Replace the reflectors &/or side panels, lamps and
covers. Plug in the unit and operate as normal. If the quartz sleeve is dirty on the
outside, proceed to wipe it down with a clean lint-free cloth and rubbing alcohol to
remove the dirt. If the quartz sleeve is dirty on the inside, proceed with in-place
cleaning or disassembly.
Caution: The quartz sleeve can break or chip if mishandled. Always handle it
with care and keep it in a safe place if it is removed from the unit. Do not strike
the quartz sleeve with any tool, since even the smallest chip can cause it to
break under pressure.