Instruction manual
Hallett 13 & 30 Instruction Manual - Wastewater & Reuse
Released on 1-May-14 – XH115B Page 28 UV Pure Technologies Inc. © 2014
6A
26A
26
27
10
19
23
22
13
18
20
11
24
8
17
14
24
15
16
5
21
REFLECTOR ASSEMBLY
REMOVED FOR CLARITY
4
1
7
8
19
28
VIEW A
A
25
24
Figure 4B – Hallett 13
Step 2: Place another bucket under the unit and drain the unit (see Draining the
Unit).
Step 3: Open the unit and remove the lamps and reflectors (see Determining the
Need for Cleaning).
Step 4: Disconnect the Stainless flexible hose from the top of the unit (8) and
remove the top quartz seal assembly.
Caution: Do not damage the sealing surfaces of the end caps (12 and 23) or the
shaft adapter of the wiper assembly (6A). Handle these parts with care to prevent