Instruction manual

Hallett 13 & 30 Instruction Manual - Wastewater & Reuse
Released on 1-May-14 – XH115B Page 6 UV Pure Technologies Inc. © 2014
prevent damage (see Draining Instructions). The water temperature range is 1–
38°C (34–100°F). Special Note: Drafts or areas where cold air is blowing on the
system can adversely affect the temperature – make sure the system is free from
cold air currents). If cold room conditions cannot be avoided, the Cold Air Kit
should be installed.
Energy Requirements:
There are two standard operating voltages for the Hallett unit. The unit may be
120Vac or 220-240 Vac. Please refer to the power input label located near the
power cord entry of the unit. See Figure 1B. Record the operating voltage and
serial on the front cover of the manual.
120Vac Models 220-240Vac Model
Hallett 13 – 104W, 1.5A max. 50/60Hz Hallett 13 -108W, 1A max. 50/60Hz
Hallett 30 - 173W, 1.5A max. 50/60Hz Hallett 30 -177W, 1A max. 50/60Hz
UV Pure supplies Transient Voltage Surge Protectors (that have been certified to
UL1449 standard or equivalent that includes integral Over/Under Voltage shutoff
protection) with its Hallett and Upstream models in North America to help protect
against damage from power fluctuation. Those models must be plugged into the
supplied protectors in North America, and into equivalent protectors outside
North America (not supplied with systems in those markets).
UV Pure Technologies’ UV water purification system models are designed to
operate within normal power grid specifications (voltages and frequencies),
worldwide. However power spikes, surges and brownouts are a common
occurrence in all countries. When that happens, line voltages may fluctuate
outside the systems’ operating specifications.
Installation of the supplied TVSS/SPD between the UV system and the power
source will increase the ability of the system to survive transient events on the
AC power. This will help to ensure uninterrupted water treatment and reduce the
risk of costly repairs due to damage from power spikes, surges and brownouts
which are NOT COVERED BY UV PURE TECHNOLOGIES’ Limited Warranty.
Safety Information
GROUNDING
This UV unit must be grounded. In the event of a malfunction or breakdown,
grounding will reduce the risk of electric shock by providing a path of least
resistance for electric current. This unit is equipped with a cord having an
appliance-grounding conductor and a grounding plug. The plug must be plugged
into an appropriate outlet that is installed and grounded in accordance with all
local codes and ordinances. The piping connected to the UV unit must also be
properly grounded. Install a grounding lug or strap as required.
WARNING - Improper connection of the equipment-grounding conductor can
result in a risk of electric shock. Check with a qualified electrician or service
representative if you are in doubt whether the unit is properly grounded. Do not
modify the plug provided with this unit; if it will not fit the outlet, have a proper
outlet installed by a qualified electrician.