Instruction manual
Hallett 13 & 30 Instruction Manual - Wastewater & Reuse
Released on 1-May-14 – XH115B Page 7 UV Pure Technologies Inc. © 2014
GROUND-FAULT CIRCUIT-INTERRUPTER
To comply with National Electrical Code, NFPA 70, the circuit where the UV
unit(s) is connected must be protected by a ground-fault circuit-interrupter
(GFCI). UV Pure recommends the use of Hubbell GFICs
WARNING: Potential Shock Hazard
Use only a grounded electrical outlet when connecting the unit to a
power source. If an extension cord is necessary, the cord should
contain a ground and be rated for the same amperage as the unit or
combined units. Do not plug in unit if water is present on the unit.
WARNING: Ultraviolet Light Hazard . The lamps in the unit emit
ultraviolet (UV) light that can cause permanent damage to the skin &
eyes. Never look at the lamp when it is operating. Do not plug the
unit in unless it is properly secured to a wall (see Installation
Instructions) and all the covers are installed. Do not remove any cover
unless the unit has been unplugged. Never look into the unit or place
any exposed skin into the illuminated areas when it is operating. Do not
operate a unit that has been damaged or missing any components.
The Hallett unit is not intended for use by young children or infirm
persons without supervision. Young children should be supervised to
ensure that they do not play with the Hallett unit.
Parts Included
Hallett UV system complete with integral wall brackets (1)
Ultraviolet lamps (2) – installed within the unit
Instruction manual (1)
Power cord (1) (located within packaging)
Transient Voltage Surge Suppressor (TVSS)/Surge Protective Device
(SPD) for North American markets (120Vac systems)
Stainless flexible hoses (2) per system, for bottom inlet & top outlet
– Hallett 13: two 3/4” hoses
– Hallett 30 - 1”: two 1” hoses
– Hallett 30 – 1.5”: two 1.5” hoses
External alarm contact for remote monitoring.
Pipe wrap insulation for top hose
Cold Air Kit complete with installation instructions for Hallett 30 units (If
not immediately used, keep in a safe place. Do not discard these
items)
Other Materials Needed
The Hallett requires male NPT fittings for the hose connections (make a note of
the size 3/4”, 1”, 1.5”). These fittings and any piping compatible with the plumbing
should be on hand before you begin installation. See Figure 1B and make a list
of all necessary components including solder, paste and thread sealant. Bypass
piping and valves that isolate the unit are optional, as is a drain valve for draining
the unit.
Pipe insulation is provided to wrap around the top hose coming out from
UVUVUV