User's Manual

CrossFire HP All-Digital Transport System
User Guide
© SUNWAVE COMMUNICATIONS LIMITED 2015 44 Revision 05
OP-AU1 CPRI Sync Alarm
CPRI SYNC alarm for Port “ AU1”
RD
OP-AU2 CPRI Sync Alarm
CPRI SYNC alarm for Port “ AU2”
RD
OP1~6LOS Alarm
Loss of optical signal alarm for Port “OP1~OP6
RD
OP-AU1 LOS Alarm
Loss of optical signal alarm for Port “AU1”
RD
OP-AU2 LOS Alarm
Loss of optical signal alarm for Port “AU2”
RD
Table 20 AU Advanced Commands
Command
Description
RD/RW
Master / Slave AU Select
Master AU / Slave AU select
RW
Modem Type
Reserve
RD
Backup Battery Switch
/
RW
Hardware Reset
Noted
Signal interruption during hardware reset
RW
Software Reset
Noted
Signal is normal during software reset
RW
Wi-Fi Module Reset
/
RW
Initialization/Alarm Report
Initialization: Clear alarms and disable all alarms;
Report Site launch: Report to OMC when new site launches;
RW
Alarm Mode Selection
Normal mode: 3 minutes
Test mode: 1 minute
RW
3.7.8. AU Command
Table 21 AU Factory Parameters
Factory Pattern
To perform Delete all Slave-Devices or Device Initialization functions,
factory authorization is required.
RW
Factory Pattern Password
Reserve
RW
4. EU Instructions
4.1. EU Physical Appearance
Figure 4-1 shows a photograph of the EU component of the CrossFire.