User's Manual

CrossFire HP All-Digital Transport System
User Guide
© SUNWAVE COMMUNICATIONS LIMITED 2015 47 Revision 05
4.5.1. EU User Parameters
Table 24 EU Device Information
Parameter
Description
RD/RW
Vendor
Name to distinguish from different manufacturers
RD
Product Model
/
RD
Serial Number
/
RD
RMON Mode
Current remote monitoring mode
RD
Software Upgrade Result
/
RD
Remote Upgrade Mode
/
RD
RMON Edition
Current edition of remote monitoring software
RD
Device Edition(FPGA)
Device edition defined by FPGA
RD
Device Location
/
RW
Table 25 EU Network Management
Parameter
Description
RD/RW
Site ID
The unique identification number of site in the system assigned by
Master AU
RW
Device ID
Number to distinguish the subsets in the same site assigned by
Master AU
RW
Date and Time
/
RW
4.5.2. EU Alarms
Table 26 CrossFire Alarms for the EU
Parameter
Description
RD/RW
Power Interruption Alarm
Electric supply failure
RW
MOV Alarm
Alarm when device leave the original installation location
RW
Open Case Alarm
Alarm when device is open
RW
Over-temperature Alarm
Alarm when device temperature over rated temperature threshold
RW
DPLL Unlocked Alarm
Digital phase lock loop unlocked
RW
OP-transceiver1~6 Failure Alarm
OP-transceiver unplugged or failure (Port OP1~OP6)
RW
OP-slave transceiver Alarm
OP-transceiver unplugged or failure (Port SLAVE)
RW
OP-master transceiver Alarm
OP-transceiver unplugged or failure (Port MASTER)
RW
Link Alarm
Alarm when local EU cannot connect to the system
RW
4.5.3. EU System Info
Table 27 EU Sampling Info
Parameter
Description
RD/RW
Over-temperature Threshold
Default value: 80/ Range: -55~ +125
RW