User's Manual

CrossFire HP All-Digital Transport System
User Guide
© SUNWAVE COMMUNICATIONS LIMITED 2015 69 Revision 05
6.4.1. Optical Interface Connection
Single Optical Fibre-module
Figure 6-13 shows that when using a pair of single optical fibre-modules, the wavelength of the two modules
should be different, for example, 1271nm & 1331nm. See Table 51 for the optical fibre module corresponding to each
port. When the optical module is unplugged or not synchronized, the indicators are red as shown in the left pair of
indicators in Figure 6-15. Check whether both indicators turn green after connecting one pair of optical modules. If they
are red, the terminal has not synchronized. See Section 9 for how to resolve this issue.
Table 51 Optical Module Selection for Single Optical fibre-module
Device Unit
Port
Wavelength of Module
Master AU
All Ports
1271nm
Slave AU
OP1 (only this port is used)
1331nm
EU
Slave
1331nm
Master & OP1~OP6
1271nm
RU
Slave
1331nm
Master
1271nm
Figure 6-13 Single Optical Fibre Module
Double Optical Fibre-module