User's Manual

CrossFire HP All-Digital Transport System
User Guide
© SUNWAVE COMMUNICATIONS LIMITED 2015 75 Revision 05
Connection & Query Status
Alarm Parameter Configuration
Completion
Figure 7-2 EU Debugging Procedures
7.1. Network Management System Setup for SNMP
The site number must be set using the WebOMT on the Master AU before connecting to the network management
system (NMS). The NMS should identify devices by their unique site number. Network parameters also need to be set up
for the specific network. If the NMS supports the SNMP protocol, set Protocol Select to “SNMP” and configure related
parameters such as the Trap IP Addr, Trap Port, Subnet Mask, Default Gateway, etc. as shown in Table 7. If the NMS
supports the SUNWAVE proprietary protocol, set Protocol Select to TCP/IP” and configure the corresponding
parameters as shown in Table 6.
The remote FTP server parameters also need to be set up if remote software upgrades are supported. These
parameters are set in the Engineering tab ―> User Para sub-tab in the WebOMT. See Figure 7-3 for details.