User's Manual

CrossFire HP All-Digital Transport System
User Guide
© SUNWAVE COMMUNICATIONS LIMITED 2015 78 Revision 05
AU is 0dBm and the maximum allowable input power is 10dBm. Therefore, before accessing the RF signals, estimate the
signal power. Monitor the downlink input power with a spectrum analyzer or read the downlink input power from the
“Digital Info” on the WebOMT in order to set the downlink input power within the appropriate range. The adjustable
attenuation value of each AU channel is 5dB, which can be set in Engineering ―> Real-time Info ―> RF Channel x.
See Figure 7-5 for details.
Figure 7-5 Channel Gain Adjustment
7.4. Alarm Parameters Setup
After completing the radio-frequency channel properties configuration, set up the alarm parameters using the
following procedure:
1. In the WebOMT, select the Engineering tab.
2. Set the status of the optical transceiver one by one.
3. If there is an optical path connection, enable the basic device alarms, such as Power Interruption Alarm,
Battery failure Alarm, MOV Alarm, etc.
For alarms related to channel properties, such as the DPLL unlocked Alarm, LO unlocked Alarm, OP transceiver
failure Alarm, etc., only enable those associated with the channels which have an input signal, to avoid unnecessary
alarms. See Figure 7-6 for details.
Wait 3~5 minutes after completing the setup, then query to see if there is a failure alarm for the device. If there is
an alarm, see Section 9 to resolve the issue.