User's Manual

CrossFire HP All-Digital Transport System
User Guide
© SUNWAVE COMMUNICATIONS LIMITED 2015 89 Revision 05
Operator E
Operator C
Operator A
Fiber
Master AU
Slave AU
EU
Fiber
Fiber
Fiber
POI
A
B+C
D
E
F
RU
RU
Fiber
POI
A
B+C
D
E
F
RU
RU
Fiber
Operator D
Site 1
Site 2
Operator B
Operator F
Different operator
input be combined into
one RF channel
RU cascade to increase RF
channel
Figure 10-2 Example for Operators Located at Separate Sites
10.3. MIMO Application
Since the same frequency is used between MIMO1 and MIMO2, operator C, as shown in Figure 10-3, must employ
two special channels in the AU and RU. In order to guarantee coherence between MIMO1 and MIMO2, MIMO1 and
MIMO2 must be in the same AU and RU. The maximum bandwidth per operating band should be less than 60MHz and
the maximum bandwidth of all operators should be less than 200MHz.
Operator A
WCDMA
Operator B
WCDMA
Operator C
LTE MIMO
AU
EU
Fiber
Fiber
POI
A
B
MIMO1
RU
MIMO
MIMO2
Figure 10-3 Example for MIMO Application
10.4. RU Cascade Application
In this scenario, RU1 can connect to the EU or directly to the AU. A maximum of four RUs can cascade when RU1 is