0102 095 52541 18”Inset Raised User, Installation & Servicing Instructions This appliance is for use on NATURAL GAS (G20) ONLY at a supply pressure of 20mbar Please hand this booklet to the user and advise to keep in a safe place Important Notice: Before disposal of the outer packaging, please enter the product code, purchase and installation details in section 1.1 of this booklet.
This booklet details instructions for USER (section 1), INSTALLATION (section 2) & SERVICING (section 3). IMPORTANT NOTICE It is important for the safe and continued operation of this appliance that the instructions contained in this booklet are observed! TABLE OF CONTENTS Section Section 1.0 Instructions for Use 1.1 1.2 1.3 1.4 1.5 1.6 Record of purchase/installation Important notes Lighting and extinguishing the appliance Re-laying the coal/pebble bed Spare parts Guarantee 2.
Section 1 – Instructions for Use 1.
1.2 IMPORTANT NOTES 18 “ Inset CAUTION – THIS PACKAGE WEIGHS 6.5Kgs – assess the load before you move it and note any other handling information on the packaging. If you think the load is beyond your safe capability, DO NOT PUT YOURSELF AT RISK! Seek assistance from other person(s) and/or use appropriate handling equipment. IT’S YOUR BODY – LOOK AFTER IT! This appliance is for DECORATIVE PURPOSES ONLY and is manufactured to the requirements of the current issue of EN 509.
1.4 RE - LAYING THE BED 18 “ Inset Fig. 3 The support shelf is positioned on the fibre support metalwork. There are two metal `stops’ that prevent the support shelf from sitting on the main burner outlet (Fig. 3). Fig. 4 Metal `stops’ The simulated front is positioned on the shelf directly in front of the support shelf. Two metal `stops’ locate the simulated front in position.
1.5 SPARE PARTS 18” Inset For a list of spare parts for this appliance, please refer to section 3.3. 1.6 GUARANTEE Please complete the registration section of the white card supplied in the IFU kit. Any part of this appliance is guaranteed against the manufacturer’s defective workmanship or faulty materials for a period of twelve months from the date of purchase. Any such part will be replaced free of charge on receipt of the purchaser’s address at the cost of postage only.
Section 2 – Instructions for Installation 2.1 IMPORTANT NOTES 18” Inset CAUTION – THIS PACKAGE WEIGHS 6.5Kgs – assess the load before you move it and note any other handling information on the packaging. If you think the load is beyond your safe capability, DO NOT PUT YOURSELF AT RISK! Seek assistance from other person(s) and/or use appropriate handling equipment.
2.3 TECHNICAL DATA 18” Inset Fig. 7 Fig. 8 Minimum height of opening is 555mm Minimum Depth of opening is 215mm 295mm 215mm Minimum width of opening is 415mm 415mm SPECIFICATIONS 2.4 Injector 044/341/196/087M Gas Control MP 21301B Main Burner Aeromatix AC03/211658 Thermocouple T100/927-400 Ignition Single spark electrode direct to main burner Gas Connection 8mm OD (restrictor elbow) Gas Type G20 NATURAL GAS Maximum Heat Input 7.8kW (26.003btu/hr) Gross Minimum Heat Input 3.
2.4.1 INSTALLING THE APPLIANCE (Flue) 18” Inset Any permanent flue restriction must be removed and any variable dampers locked fully open or removed. If the flue has been used previously for solid fuel, it MUST be swept PRIOR to installation. This appliance is suitable for installation into CLASS 1 flues ONLY.
2.4.3 INSTALLING THE APPLIANCE (Hearth clearances) 18” Inset A non-combustible hearth with a minimum thickness of 12.5mm and having a perimeter of 50mm above floor level is required to discourage placing carpets or combustible materials close to the hearth. The width must be a minimum of 150mm either side of the fireplace opening and a depth of 300mm from the front face of the fire opening (Fig. 12). Fig.
2.4.4.2 INSTALLING THE APPLIANCE (Checking the appliance setting pressure) 18 “ Inset The pressure test point enables verification of the inlet pressure at the appliance under operating conditions and can also be used to check the gas soundness of the connections to the appliance gas controls (Fig. 14). Fig. 14 Restrictor elbow c/w PTP (Pressure Test Point) Control knob Piezo ignitor Rating label 2.4.4.3 INSTALLING THE APPLIANCE (Checking the correct operation) 1. Remove the fret (Fig.
2.5 LAYING THE BED 18 “ Inset Fig. 17 The support shelf is positioned on the fibre support metalwork. There are two metal `stops’ that prevent the support shelf from sitting on the main burner outlet (Fig. 3). Fig. 18 Metal `stops’ The simulated front is positioned on the shelf directly in front of the support shelf. Two metal `stops’ locate the simulated front in position.
2.6 CLEARANCE OFCOMBUSTION PRODUCTS 18” Inset . Relight the appliance and allow to run for five minutes with the gas control in the `HIGH’ position. Check for satisfactory clearance of combustion products by inserting a lighted smoke match into the opening 100mm below the top of the opening and 10mm in from the face of the surround (Fig. 21). Smoke match to be positioned 100mm down and 10mm in from this point Fig. 21 The majority of smoke must be drawn up into the flue.
Section 3 – Maintenance & Servicing 3.1 REMOVAL OF DEBRIS OR SOOT 18” Inset Allow the appliance to cool for two to three hours before removing all of the fibre components for cleaning purposes. Once all the fibre is removed, check that no debris is located in the burner holes of the appliance. If any debris is located, carefully remove any foreign matter from the burner holes. Any soot deposits or debris left on the fibre components may be removed by using a soft brush.
18” Inset 16 15 13 18 4 9 10 12 17 1 5 3 14 2 6 8 11 7 Fig. 27 3.3 SPARE PARTS PART DESCRIPTION 1 2 3 4 5 6 7 8,9 10 11 12 13 14 15 16 17 18 Aeromatix Burner (Natural Gas) (Manuf No AC03/211658 ) Piezo Ignitor c/w Steel Nut (Manuf No 66142/100) 087M Straight Injector (Manuf No 044-341-196-087M) Ignition Lead (250mm) Inlet Bundy Gas Valve (Aero Burner) (Manuf.
3.4 USEFUL TELEPHONE NUMBERS In the event that you may require service, spares or technical information, please contact us at: Crosslee PLC Halifax West Yorkshire HX3 8DE Customer Service Service Engineer (REPAIRCARE) Telephone 01422 203963 0844 8797422* Fax 01422 204767 *Calls cost 5p per minute from a UK BT landline. Charges from mobile and other network providers may vary.