0102 095 50042 INSET – FLAME SYSTEM 1 USERS (Pages 2-3)/ INSTALLATION (Pages 4-7) AND SERVICING INSTRUCTIONS THIS CAT I2H APPLIANCE IS FOR USE ON NATURAL GAS G20 AT A SUPPLY PRESSURE OF 20mbar IN GB and IE HAND THESE INSTRUCTIONS TO THE USER
USERS INSTRUCTIONS DESCRIPTION The Royal Cozyfire is a decorative gas fire designed to fit into a conventional fire surround and fireplace. It should be fitted to a flue that conforms to a conventional Class I flue (i.e. a brick built chimney of 227 x 227mm (9x9ins) or 175mm (7ins) diameter lined or stone chimney with the fire back and fireplace components complying to BS1251.
Page 2 4. Depress the gas control slightly and turn anti-clockwise until the indicator mark is aligned with the HIGH symbol. The burner will cross light from the pilot. 5. Depress the gas control slightly and turn anti-clockwise until the indictor mark is aligned with the LOW symbol. The burner will now be at minimum rate. 6. To turn the appliance ‘off’, return the control to the ‘OFF’ position 7.
INSTALLATION and SERVICING INSTRUCTIONS THE FOLLOWING SECTION LISTS THE INSTALLATION REQUIREMENTS AND REGULATIONS All gas appliance installations must be installed by a competent person in accordance with the current Gas Safety (Installation and Use) Regulations or the rules in force and in accordance with the attached Installation Instructions; failure to do so could lead to prosecution.
Site the appliance as far back as possible whilst maintaining a central position in the opening, establish where the fixing holes are to be. A bracket is supplied in the fixing kit; this can be located either to the front or to the rear of the fascia panel. To the rear the fixing holes will probably coincide with a concrete base within the opening that will prevent drilling into a marble hearth etc. Alternatively the bracket can be reversed to allow access to the front of the fascia panel see fig. 3.
TO LIGHT THE APPLIANCE AND CHECK THE CORRECT OPERATION 1. Remove the fret (controls cover), to gain access to the controls. 2. Press and turn the gas control anti-clockwise, keep the control fully depressed to purge the air from the pipework. Turn ‘OFF’ and repeat the operation, check that a spark occurs between the electrode and the head of the pilot. The pilot will light, if not repeat the operation. 3. 0nce a pilot-flame has been established; keep the control depressed for a further 20 seconds.
Page 6 MAINTENANCE AND SERVICING GENERAL A. REMOVAL OF DEBRIS or SOOT DEPOSIT Allow the appliance to cool for two to three hours before removing all of the coals and ceramic blocks for cleaning purposes. Once all the ceramics are removed from the fire bed check that no debris is located in the burner slots. If any debris is present it may easily be removed by using a small piece of thin cardboard to ease out any foreign matter. Be sure to remove the cardboard after use.
Page 7
Page 8 MAX HEAT INPUT (GROSS) 6.6 kW 22450 Btu/hr Royal Cozyfires are manufactured by: CROSSLEE plc Aber Park Industrial Estate, Aber Road, Flint, Flintshire.