To Dismantle the Appliance Prior to Installation
Remove the two screws securing the burner in position, (See Fig. 4) carefully pull the burner forward (taking
care to avoid placing any stress an the wires supplying power to the solenoid valve. Fig.7). Disconnect the
cable at the small plug and socket by lifting the small locking lever. This will give access to the heat shield
covering the control box and wiring connections. Unscrew the securing screw and lift the cover from the
control box mounting plate see Fig. 8. This will be necessary to change the orientation of the mains supply
cable or run the gas supply to from the right hand side of the appliance,
Page 8
Because of the varied constructions to
which the appliance can be installed and
the various surrounds used, the following
guidelines have been divided into
sections to assist with the installation of
the appliance.
A. Non-combustible walls.
(i) Free standing with false chimney -
breast.
(ii) Free standing with fire surround (see
specific instructions for individual
surrounds)
B. Inset into inner leaf of a non-
Combustible walled construction.
C. Timber framed buildings.
(i) Free standing with false chimney-
breast.
(ii) Free standing with a fire surround.
D Combustible cladding
(I) Free standing with a fire.
A1
When the fire is to be fitted to a non-
Combustible wall i.e. brick blockwork or
similar and the position of the proposed
flue outlet terminal is satisfactory work
can proceed on installing the fire, and a
false chimneybreast.
The fire must always be fitted with a
hearth, the minimum sizes as shown in
Fig 2