Where the appliance is to be installed against a wall, a Rockwool gasket is provided to slide over the flue
before the appliance is placed in position. The function of this is to form a seal between the rear of the
appliance and the cavity between the inner and outer walls of a cavity wall construction. See Fig. 8.
Where a space is required between the inner wall and the appliance the cavity will need to be sealed using the
Rockwool gasket held against the wall by the closure plate secured by the three countersunk screws supplied.
See Fig. 9.
The appliance must be fixed in position either against the wall or spaced away from the inner wall using the
holes in the two ears at the top of the appliance. Two additional fixing positions are provided 2 holes in the
base of the appliance or 2 holes in the rear of the appliance.
Before the false chimneybreast is constructed the installation of the appliance can be completed and tested,
details of which appear in later sections.
Guide lines for the construction and the minimum clearances required when combustible materials are being
used are shown in Fig. 2. These indicate that if studwork and plasterboard is to be used precautions must be
taken to ensure that a gap of 75mm is provided from all the surfaces of the appliance to any combustible
material, this dimension can be reduced to 25mm if 25mm thick insulation material is used.
For installation into false chimneybreasts, two brass trims are available to complement the appearance of the
appliance. They are listed in the spares section.
The Turbo Toaster trim can be adjusted to finish flush with the front of the appliance or to protrude forward of
the appliance from 0mm to 30mm (See page 25, Fig. 25).
The prince trim has a flange of 50mm around the inside of the opening for situations where the fire is inset
into an opening (See page 24, Fig. 22).
Lay the hearth to the dimensions stated if one has not previously been installed as part of the construction.
Page 10
A 2
To install the Turbo Toaster into propriety
hearth and surround care must be taken to
select one that is compatible with the size
and temperature requirements of the
appliance. The minimum fire resistance
specification is Class O (100
O
C) for the
hearth and panel that is to be used.
Apart from the purpose designed and built
Be Modern Royal Harmony Hearth and
Surround most surrounds will require a false
chimneybreast to be constructed prior to
fixing the surround.
Most of the details in A1 for installing the
appliance are relevant, although the actual
depth of the chimneybreast may depend.