User manual

Description
The Turbo-Toaster Mklll is a decorative gas fire that has been designed for use in applications that do not have
a conventional chimney or flue but where an appliance can be located so as the flue can terminate on an
outside wall.
The flue has a built-in canopy with a horizontal flue duct running through the wall terminating with a fan
housing box attached to the exterior wall.
A control box is positioned on the right hand side of the appliance behind the front and fret. This operates a 2-
speed fan via an ON button with a neon lamp indicating that an adequate flow of air has been established
through the flue. When the flow-sense switch has been activated, the neon lamp goes out indicating that the
manually operated gas control can be used. A piezo igniter is used to ignite the Oxy-pilot mounted on the
fascia panel and when a pilot flame has been established the gas control can then be used to ignite the main
bumer.
The burner assembly is similar to that now used successfully on our range of appliances; namely a twin ported
ribbon burner running parallel across the width of the fire bed. Ceramic components are used to protect
various items from excessive heat and to re-radiate heat into the fuel bed. There is a one-piece ceramic fibre
chairbrick used to maximise the radiated heat from the fuel bed and therefore increase the efficiency of the
appliance.
To extinguish the appliance, turn the gas control to the off position and push the off button on the control box
to stop the fan running. If required, the fan can be left running for ventilation purposes.
A wide scope exists for many applications ranging from special surrounds to simulated surrounds and purpose
built installations. A hearth must be provided and all the relevant precautions adhered to. The fire is designed
to suit different styles of trims and surrounds. The BE MODERN HARMONY fire surround and hearth is
designed for specific use with the Turbo Toaster MK III.
There are special requirements for installations in timber framed dwellings relating to minimum clearances
between any part of the fire or flue and combustible materials. These are stipulated in the building regulations
for the shielding of flue pipes for class II appliances BS 5871 Pt. 3 1991 A timber frame fixing kit is available
from your supplier, for installations into timber framed dwellings.
The Turbo Toaster is designed and manufactured to the requirements of SIT 8 Document (88/91374) and is for
use on Natural Gas only,
All gas installations must be carried out by a competent person in accordance with the installation Instructions
and with the Gas Safety (Installation and Use) 1994 Regulations or the rules in force. All Electrical
Installations must comply with the Electrical Equipment (Safety Regulations); failure to comply could lead to
prosecution.
WARNING IMPORTANT
THIS APPLIANCE MUST BE EARTHED The wires in the mains lead are coloured in accordance
with the following code.
This appliance requires a 3-amp fuse. Green & Yellow - Earth
Blue - Neutral
Brown - Live
Page 2