User manual

12. TO SERVICE THE FAN MOTOR
Disconnect the electrical supply.
Remove the terminal guard if fitted, fan box cover and deflector plate as detailed in 11.1 to 11.3.
Disconnect the electrical connections to the fan at the terminal block and earth post noting their positions.
Unscrew the three hex headed screws on the perimeter of the fan motor assembly mounting plate and
withdraw the fan and impeller assembly leaving the fan scroll in situ. Clean any soot or lint from the fan
impeller and casing.
Reassemble all components in reverse order of removal. Refer to the wiring diagram for the electrical
connections and figs 23 & 26.
Page 24