User manual

IMPORTANT: After turning OFF, or if the pilot and appliance go out for any other reason, wait for 3
minutes before attempting to relight.
NOTE: The appliance is fitted with an Oxy-pilot to prevent the continued operation in the event of spillage
occurring. If the fire shuts off’ repeatedly the appliance must be turned off and not used until an expert is
consulted.
Relaying the coal bed after cleaning (see Figs. 1,2 &3)
It is recommended that all coals and the ceramic blocks be removed for cleaning purposes.
Once all the ceramics are removed from the firebed, check that no debris has located in the burner slots (both
front and rear). If any debris is present it may be easily removed by using a small piece of thin cardboard to
ease out any foreign matter, be sure to remove cardboard after use.
The firebed can now be replaced. It is important that these instructions are followed carefully.
Replace the two burner inserts ensuring that the base of the fibre block sits inside the two parallel burner ports.
Now replace right and left-hand coal supports ensuring that the rebate is facing downwards and located over
the fibre support channel flange. The correct location of the coal supports will be verified by the presence of a
gap approximately 6mm between the front edge of the coal support and the rear edge of the burner. Note that
there are two additional stops provided for the front edge of the coal supports (fig. 1). The front simulated coal
can now be positioned on the support plate form immediately above the control panel, (Fig. 1). Note that the
two tapered edges of the simulated coal locate between the two raised flanges.
Page 4