82530 Issue 2 SUPER FERRONA 18 MKII USERS (Pages 2-3)/ INSTALLATION (Pages 4-6) AND SERVICING INSTRUCTIONS THIS CAT I2H APPLIANCE IS FOR USE ON NATURAL GAS G20 AT A SUPPLY PRESSURE OF 20 mbar IN GB and IE HAND THESE INSTRUCTIONS TO THE USER
DESCRIPTION The Super Ferrona 18 MKII is a decorative gas fire designed to fit into a conventional fire surround and fireplace. It must have a flue that conforms to a conventional Class I flue (i.e. a brick built chimney of 227 x 227mm (9x9ins) or 175mm (7ins) diameter lined or stone chimney with the fire back and fireplace components complying to BS1251.
TO LIGHT THE APPLIANCE 1. Remove the fret (controls cover). 2. Press and turn the gas control until the indicator mark is opposite to IGN. Keep the control fully depressed. Press and release the ignition button. Check that the pilot flame is lit. Keep the gas control depressed for a further 20 seconds. Release the gas control and check the pilot remains alight. 3. Depress the gas control slightly and turn fully anticlockwise until the indicator mark is opposite the small flame symbol.
THE FOLLOWING SECTION LISTS THE INSTALLATION REQUIREMENTS AND REGULATIONS The following relevant Codes of Practice and British Standards are: BS 544O BS 544O BS 6461 BS 5871 BS 6891 BS 83O3 BS 1251 Part 1 Part 2 Part 1 Part 3 199O 1989 1984 1991 1988 1994 1987 The Building Regulations issued by the Department of the Environment. The Building Standards (Scotland) (Consolidation) Regulations issued by the Scottish Development Department.
Site the appliance as far back as possible whilst maintaining a central position in the opening, establish where the fixing holes are to be. With the bracket located to the rear of the fascia panel, the fixing holes will probably coincide with a concrete base within the opening, this will prevent drilling into a marble hearth etc, access to these two holes is through two of the large holes above the fascia panel.
TO LIGHT THE APPLIANCE AND CHECK THE CORRECT OPERATION 1. Remove the fret (controls cover). 2. Press and turn the gas control until the indicator mark is opposite to IGN. Keep the control fully depressed. 3. After a suitable interval to ensure that the pipes are purged of air, press and release the ignition button. Check that the pilot flame is lit. Keep the gas control depressed for a further 20 seconds. 4. Release the gas control and check the pilot remains alight. 5.
MAINTENANCE AND SERVICING GENERAL A. REMOVAL OF DEBRIS or SOOT DEPOSIT Allow the appliance to cool for two to three hours before removing all of the coals and ceramic blocks for cleaning purposes. Once all the ceramics are removed from the fire bed check that no debris is located in the burner slots (both front & rear). If any debris is present it may easily be removed by using a small piece of thin cardboard to ease out any foreign matter. Be sure to remove the cardboard after use.
SHORT PARTS LIST For spares contact the manufacturer at the address overleaf.
MAX HEAT INPUT (GROSS) 8 kW 27300Btu/h Royal Cozyfires are manufactured by: CROSSLEE plc Aber Park Industrial Estate, Aber Road, Flint, Flintshire.
Page 9
Page 10