Instructions
U.are.U SDK - Developer Guide 76
OPOS
Claimed Yes This property is initialized to false in the open method. It is
set to true on claim and set to false again on release.
ControlObjectDescription Yes
ControlObjectVersion Yes
DataCount Partial This property is initialized to 0 in the open method and is
not modified during execution of the application.
DataEventEnabled Partial This property is initialized to false in the open method and
is set to true after a successful claim operation.
DeviceDescription Yes
DeviceEnabled Partial This property is initialized to false in the open method and
is set to true after a successful claim operation. Since the
AutoDisable property is never set to true, DeviceEnabled
always remains true.
DeviceName Yes
FreezeEvents Partial This property is initialized to false in the open method. It is
not modified during execution of the application since it is
not required to freeze events.
OpenResult Yes
OutputID No This property is not supported by the Biometrics device
category.
PowerNotify Partial This property is initialized to OPOS_PN_DISABLED in the
open method. It is not modified during execution of the
application since power reporting is not supported.
PowerState Partial This property is initialized to OPOS_PS_UNKNOWN in the
open method. It is not modified during execution of the
application since power reporting is not supported.
ResultCode Yes
ResultCodeExtended No
ServiceObjectDescription Yes
ServiceObjectVersion Yes
State Partial This property is initialized to OPOS_S_IDLE in the open
method and is set to OPOS_S_CLOSED in the close
method.
Specific Properties
Algorithm Yes See Fingerprint Data for Captures and Enrollment Tem-
plates (BIRs) on page 71 for details.
AlgorithmList Yes See Fingerprint Data for Captures and Enrollment Tem-
plates (BIRs) on page 71 for details.
BIR Yes This property holds the biometric data that is captured
and returned to the application.
CapPrematchData Partial This property is initialized to false in the open method. It is
not modified during execution of the application since the
MOC (Match-on-Card) SmartCard technology needed to
generate a processed BIR based on pre-match data
stored on a SmartCard is not supported.
CapRawSensorData Yes This property is initialized to true in the open method and
is not modified during execution of the application.
CapRealTimeData Partial This property is initialized to false in the open method and
is not modified during execution of the application.
Name
Implemented
a