3 10/2020 | GN Smart Series WWW.CROUZET.COM
General Specications
Description
35A 50A load 50A current 75A
Housing Material UL94 V-0
Baseplate Material Aluminum
Input Terminal Screw Torque Range (in-lb/Nm) - 84136120 N 4.4 -5.3 / 0.5-0.6
Load Terminal Screw Torque Range (in-lb/Nm) 18-26 / 2-3
SSR Mounting Screw Torque Range (in-lb/Nm) 11-16 /1.2-1.8
Humidity per IEC60068-2-78 40-85 %
LED Input Status Indicator Green
MTBF (Mean Time Between Failures) at 40 °C ambient
temperature (years)
48
MTBF (Mean Time Between Failures) at 60 °C ambient
temperature (years)
32
Alarm Specications
Description Load Detection Current Detection
Max. Ouput voltage
32 Vc
Max. Output current 0.1 A
On state drop voltage 0.2 V 1.4 V
Turn-off time 120 ms 70 ms
Turn-on time 20 ms 10 ms
Turn-on current - 0.9 A
Turn-off current - 0.74 A
On state resistance 2 -
Open Delay 70 ms -
Total Open Delay 120 ms -
Cheked Delay (voltage) 20 ms -
Cheked Delay (current) 20 ms -
General Notes
(1)
All parameters at 25 °C unless otherwise specied
(3)
Heat sinking required, see derating curves.
(4)
Increase minimum voltage by 1 V for operations from -20 to -40 °C.
(5)
All parameters at 50 % power rating and 100 % duty cycle (contact tech support for detailed report).
Diagrams
Wiring
GNS Smart - Load Detection
-
+
-
+
AC
+-
V
1
INPUT STATUS OUTPUT
GNS Smart - Current Detection
AC
+-
V
1
-
+
-
+
INPUT STATUS OUTPUT
GNS
B Load