Datasheet
22.5 mm DIN rail mounting TAR1 Part number 88865115
Multi
-function or mono-function
Multi
-range
Multi
-voltage
Screw or spring terminals
LED status indicator
Option of connecting an external power supply to the control input
3-wire sensor control option
Type
Functions
Timing
Output
Nominal rating
Connections
Supply voltage
88
865
105
TUR1
A - At -
B
-
C
-
H
-
Ht
-
Di
-
D
- Ac - Bw
0,1s→100h
1 changeover relay
8 A
Screw terminals
24VDC/24→240VAC
88
865
115
TAR1
A - At
0,1s→100h
1 changeover relay
8 A
Screw terminals
24VDC/24→240VAC
88
865
125
TBR1
B
0,1s→100h
1 changeover relay
8 A
Screw terminals
24VDC/24→240VAC
88
865
135
TCR1
C
0,1s→100h
1 changeover relay
8 A
Screw terminals
24VDC/24→240VAC
88
865
145
THR1
H
-
Ht
0,1s→100h
1 changeover relay
8 A
Screw terminals
24VDC/24→240VAC
88
865
155
TLR1
Li
- L
0,1s→100h
1 changeover relay
8 A
Screw terminals
24VDC/24→240VAC
88
865
175
TQR1
Q
0,1s→100h
1 changeover relay
8 A
Screw terminals
24VDC/24→240VAC
88
865
100
TUR4
A - At -
B
-
C
-
H
-
Ht
-
Di
-
D
- Ac - Bw
0,1s→100h
1 changeover relay
8 A
Screw terminals
12 V AC / DC
88
865
103
TUR3
A - At -
B
-
C
-
H
-
Ht
-
Di
-
D
- Ac - Bw
0,1s→100h
1 changeover relay
8 A
Screw terminals
12→240VAC/DC
88
865
503
TURc3
A - At -
B
-
C
-
H
-
Ht
-
Di
-
D
- Ac - Bw
0,1s→100h
1 changeover relay
8 A
Spring terminals
12→240VAC/DC
88
865
185
TXR1
Ad - Ah -
N
-
O
-
P
-
Pt
-
TL
-
Tt
-
W
0,1s→100h
1 change over relay
8 A
Screw terminals
24VDC/24→240VAC
88
865
305
TU2R1
A - At -
B
-
C
-
H
-
Ht
-
Di
-
D
- Ac -Bw
-
2 timed changeover relays
8 A
Screw terminals
24VDC/24→240VAC
88
865
215
TA2R1
A - At
0,1s→100h
2 changeover relays
8 A
Screw terminals
24VDC/24→240VAC
88
865
265
TK2R1
K
0,6s→160s
2 change over relays
8 A
Screw terminals
24VDC/24→240VAC
88
865
300
TU2R4
A - At -
B
-
C
-
H
-
Ht
-
Di
-
D
- Ac - Bw
0,1s→100h
2 timed relays changeover relays
8 A
Screw terminals
12 V AC / DC
88
865
176
TQR6
Q: Star / Delta
0,1s→100h
1 change over relays
8 A
Screw terminals
230V→440VAC
88
865
303
TU2R3
A, B, C, H, Di, Ac, BW + (At, Ht, D)
0,1s→100h
2 timed changeover relays
8 A
Screw terminals
12→230VAC/DC
88
865
385
TX2R1
Ad - Ah -
N
-
O
-
P
-
Pt
-
TL
-
Tt
-
W
0,1s→100h
2 timed changeover relays
8 A
Screw terminals
24VDC/24→240VAC
Timing
Timing ranges (7 ranges)
1 s - 10 s -
1 min
-
10 min
- 1 h - 10 h - 100 h
TK2R1: 0.6s
- 2.5s - 20s - 160 s
Repetition accuracy with constant parameters
±
0.5% (IEC/EN 1812
-1)
Drift Temperature
±
0,05% / °C
Drift Voltage
±
0.2% / V
Display accuracy according to IEC/EN 1812
-1
±
10% / 25°C
Minimum pulse duration typically (relay version)
30 ms
Minimum pulse duration typically (solid state version)
50 ms
Minimum pulse duration typically (relay version under
load)
100 ms
Maximum reset time by de
-energisation typically (relay
version)
100 ms
Maximum reset time by de
-energisation typically (solid
state version)
350 ms
Immunity from micro power cuts: typical
> 10 ms
Supply
Multi
-voltage power supply
Depending on version
Frequency (Hz)
50 / 60
Operating range
85 to 110% Un
(85 to 120% Un for 12V AC/DC)
Operator factor
100%
Max. absorbed power
0,6 W 24 V AC/DC
1,5 W 230 V AC
32 VA 230 V AC
Output specification
1 or 2 changeover relays, AgNi (cadmium-free)
2000 VA/80 W
Rated power
2000 VA/80 W
Maximum breaking current
8 A AC 8A DC
Minimum breaking current
10 mA / 5 V DC
Voltage breaking capacity
250 V AC/ DC
Electrical life (operations)
10
5
operations 8 A 250 V resistive
Mechanical life (operations)
5x10
6
Breakdown voltage acc. to IEC/EN 61812
-1
2.5 kV /1 min / 1 mA / 50 Hz
Impulse voltage acc. to IEC/EN 60664
-
1, IEC/EN 61812
-1
5 kV, wave 1.2 / 50
μ
s
Solid state output
Rated power
0,7 A AC/DC
20 °C (0,5 A UL)
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
13/03/2012 www.crouzet.com