DECT ULE-TMP
TEMPERATURE DETECTOR
CR-DU-TMP EURO
CR-DU-TMP USA
ELECTRONIC ENGINEERING LTD.
INSTALLATION INSTRUCTIONS
P/N 7105195REV. B (O.Z.)
Issue Date: July 6
th
, 2015
INTRODUCTION
This DECT ULE TMP detector is an advanced, fully
supervised low-current wireless detector that
includes a DECT ULE transceiver for reliable
system operation.
A dedicated cable is supplied with this device.
This DECT ULE TMP uses smart message control,
which verifies that all messages are successfully
transmitted, so that no event will be uninformed to
the system.
This DECT ULE TMP detector includes series of
messages for full communication administration
(Keep Alive, Tamper Status, Battery Status, Alert,
Configuration, etc.) as well as test transmission
signals.
FEATURES
DECT ULE RF protocol.
Low current Technology.
Powered by a single 3V Lithium battery.
Battery life: up to 4 years.
Frequency Band: All DECT Standard Bands.
Tamper Open/Close transmission.
Temperature reporting transmissions.
Keep Alive transmission.
Battery status transmission.
Bi-Color LED indications for monitoring &
Pairing.
Range up to 500m on open space.
Back tamper.
2 sensors Internal & External (optional).
Remotely configurable.
Friendly Pairing and Installation processes.
4
5
6
OPERATION
The DECT ULE TMP detector transmits the
following events data:
KEEP ALIVE A periodical transmission
indicating detector’s presence. The time interval is
configurable the minimum value is 3 seconds.
ALARM Indicating that measured Temperature
is out of defined Low / High thresholds. The Red
LED will blink once.
Temperature Monitoring A periodic
transmission (configurable) indicating the
measured Internal or External temperature.
LOW BAT A transmission indicating the battery
reached a pre-set low level (~2.5V). When Battery
level drops below Cut Off level (~2.3V) the device
will stop functioning and the Red LED will
constantly light On.
TAMPER Whenever the cover is removed from
Bracket or the device is tear off from the wall, a
message will be transmitted with “Tamper ON”
signal. When cover will be returned a “Tamper
OFF” signal will be transmitted.
PREPARE THE DEVICE FOR
INSTALLATION
1. Open the screw cover and unscrew the holding
screw as shown in Figure 1.
2. Separate the device from the Bracket by tilting
the front cover as shown in Figure 1.
3. Break one piece of the Bracket corners
according to the device installation orientation
(Horizontal/Vertical) as shown in Figure 2.
4. Genteelly connect the External Temperature
sensor cable to its location as shown in Figure
4. Be aware that the connector can be inserted
in only one direction.
5. Continue with the pairing process.
FIGURE 1 SEPARATE FROM BRACKET
7
8
9
FIGURE 2 DEVICE ORIENTATION
FIGURE 3 INSTALL THE CABLE
PAIRING PROCESS
1. Place a battery as instructed in Figure 4 and wait
until the Red LED stops blinking.
2. Initiate the Base Station pairing process.
3. Initiate the device pairing process by pressing the
pairing button for 5 seconds the pairing button
is shown in Figure 5. The Green LED will
constantly turn On. When the Green LED starts
blinking release the pairing button.
4. The device should register to the Base Station.
5. When registration process is successfully
completed the Green LED will constantly light On
for 3 seconds and then turn off.
6. If registration process failed the Red LED will
blink (remove the battery and run the pairing
process again).
10
11
12
FIGURE 4 BATTERY INSERTION
FIGURE 5 PAIRING BUTTON
SELECT MOUNTING LOCATION
It is recommended to mount the device vertically on
a flat area to get maximum range.
As the detector is a wireless transceiver, and in
order to take full advantage of its sophisticated
operation, do not install the detector in areas where
large metal objects could interfere with the
transmission of signals.
TRANSMISSION TESTS
Tamper transmission test
Changing the tamper switch state (by attaching /
removing the device to / from the Bracket) will
cause tamper transmissions. Verify receiving the
indication on your Application / Base Station.
Identification transmission test
Use your Application / Base Station and send
Identification Request to the device. The device
will start blinking the Green & Red LEDs
alternately 5 times each LED starting with the
Green LED.
Vertical
Installation