User's Manual

1
2
3
DECT ULE-PIR S
WIRELESS PIR DETECTOR
CR-DUS-PIR-EU
CR-DUS-PIR-USA
ELECTRONIC ENGINEERING LTD.
INSTALLATION INSTRUCTIONS
P/N 7101107 REV. B (O.Z.)
Issue Date: July 6
th
, 2015
INTRODUCTION
This DECT ULE S PIR detector is an advanced,
fully supervised low-current wireless detector that
includes a DECT ULE transceiver for reliable
system operation.
This DECT ULE S PIR detector includes APS
mechanism for extending the battery lives (see
below to learn more).
This DECT ULE S PIR detector includes series of
messages for full communication administration
(Keep Alive, Tamper Status, Battery Status, Alert,
Configuration, etc.) as well as test transmission
signals.
This product require professional installation in
accordance with UL 681.
FEATURES
DECT ULE RF protocol.
Low current Technology.
Powered by a single 3V Lithium battery.
Battery life: up to 4 years.
Frequency Band: All DECT Standard Bands.
Tamper Open/Close transmission.
Keep Alive transmission.
Battery status transmission.
Bi-Color LED indications for monitoring &
Pairing.
Range up to 500m on open space.
Back Tamper.
Remotely configurable.
Motion Detection up to 12m.
Friendly Pairing and Installation processes.
4
5
6
OPERATION
This DECT ULE S PIR detector transmits the
following events data:
KEEP ALIVE A periodical transmission indicating
detector’s presence. The time interval is
configurable the minimum value is 1 minute.
ALARM Alarm transmission triggered by the
device indicating Motion detection. The Red LED
will blink once.
LOW BAT Whenever the battery reaches a pre-
set low level (~2.5V), a Battery Low signal will be
sent. When Battery level drops below Cut Off level
(~2.3V) the device will stop functioning and the Red
LED will be constantly lighted On.
TAMPER Whenever the cover is removed from
Bracket or the device is tear off from the wall, a
message will be transmitted with “Tamper ON
signal. When cover will be returned a “Tamper
OFF” signal will be transmitted.
FIGURE 1 SEPARATE FROM BRACKET
FIGURE 2 SEPARATE FROM BRACKET
7
8
9
FIGURE 3 - BATTERY PLACEMENT
PAIRING PROCESS
1. Open the screw cover as shown in Figure 1.
2. Unscrew the holding screw and eparate the
device from the Bracket by tilting the front cover
as shown in Figure 2.
3. Place a battery as instructed in Figure 3 and
wait until the Red LED stops blinking.
4. Initiate the Base Station paring process.
5. Initiate the PIR pairing process by pressing the
pairing button for 5 seconds the pairing button
is shown in Figure 4. The Green LED will
constantly turn On. When the Green LED starts
blinking release the pairing button.
6. The device should register to the Base Station.
7. When registration process is successfully
completed the Green LED will constantly light
On for 3 seconds and then turn Off.
8. If registration process failed the Red LED will
blink (remove the battery and run the pairing
process again).
FIGURE 4 - PAIRING
10
11
12
SELECT MOUNTING LOCATION
Choose a location most likely to intercept an
intruder. (Our recommendation is a corner
installation). See Figure 6 - Detection Pattern. The
detector is more sensitive detecting motion
crossing the space in front of the detector then
moving toward the detector.
Recommended mounting height 1.9m-2.3m.
Avoid the following locations:
Facing direct sunlight.
Facing areas that may change temperature
rapidly.
Areas where there are air ducts or substantial
airflows.
This device detect or performs better when
provided with a constant and stable environment.
MOUNTING THE DETECTOR
1. Open the screw cover as shown in Figure 1.
2. Unscrew the holding screw and eparate the
device from the Bracket by tilting the front
cover as shown in Figure 2.
3. Mount the Bracket to the wall: place 3 screws
and make sure you tighten the tamper screw -
the middle screw.
4. For flat mounting on a wall use the middle 3
screws location as shown in Figure 5. For
mounting in a 45 degrees position, use the 3
screws locations on the bracket’s sides.
5. Place a battery as instructed in Figure 3 and
wait until the Red LED stops blinking.
6. Initiate the Pairing process.
7. Place the device in the Bracket by inserting it
back into appropriate position.
8. Fasten holding screw and close screw cover.
Note: The Detector can be mounted to a Wall/Celling
using an optional Wall/Celling Mount Bracket or
Adhesive Tapes for more details see Crow P/N
7104107 REV. A.
FIGURE 5 - INSTALLATION