CE Series Operation Manual CE 4000 Obtaining Other Language Versions: To obtain information in another language about the use of this product, please contact your local Crown Distributor. If you need assistance locating your local distributor, please contact Crown at 574-294-8000. This manual does not include all of the details of design, production, or variations of the equipment. Nor does it cover every possible situation which may arise during installation, operation or maintenance.
CE 4000 Power Amplifier Important Safety Instructions 1) 2) 3) 4) 5) 6) 7) Read these instructions. Keep these instructions. Heed all warnings. Follow all instructions. Do not use this apparatus near water. Clean only with a dry cloth. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus that produce heat.
CE 4000 Power Amplifier Crown International, Inc. DECLARATION OF CONFORMITY Issued By: Crown International, Inc. 1718 W. Mishawaka Rd. Elkhart, IN 46517 U.S.A. Sue Whitfield 574-294-8289 swhitfield@crownintl.
CE 4000 Power Amplifier Table of Contents Important Safety Instructions .................................................... 2 5.1.2 Fault...................................................13 1 Welcome .................................................. 5 5.1.3 High-Pass Filter .................................13 1.1 Features........................................................... 5 5.2 Circuit Design .............................................13 1.2 Unpacking Your Amplifier.....................
CE 4000 Power Amplifier 1 Welcome ® Crown CE 4000 amplifiers have been engineered from the bottom up to provide superior power output, increased efficiency, legendary Crown sound and extraordinary reliability. They were designed using Crown’s patented, award-wining BCA® (Balanced Current Amplifier) engineering. • Sub-bass output via integral 4-position high-pass and 3-position low-pass filter sets for each channel.
CE 4000 Power Amplifier 3 Setup 3.1 Unpack Your Amplifier 3.2 Install Your Amplifier 3.3 Ensure Proper Cooling YOU WILL NEED (not supplied): CAUTION: Before you begin, make sure your amplifier is disconnected from the power source, with power switch in the “off” position and all level controls turned completely down (counterclockwise). When using an equipment rack, mount units directly on top of each other. Close any open spaces in rack with blank panels. DO NOT block front or rear air vents.
CE 4000 Power Amplifier 3 Setup 3.4 Choose Input Wire and Connectors Balanced Line Unbalanced Line Crown recommends using pre-built or professionally wired, balanced line (two-conductor plus shield), 22-24 gauge cables and connectors. Depending upon which amplifier input you choose, you should use either 3-pin male XLR connectors, TRS phone connectors, or terminal forks at the amplifier inputs. Unbalanced line may also be used but may result in noise over long cable runs.
CE 4000 Power Amplifier 3 Setup 3.5 Choose Output Wire and Connectors Crown recommends using pre-built or professionally wired, high-quality, two- or fourconductor, heavy gauge speaker wire and connectors. If your amplifier includes Neutrik® Speakon® outputs, use male Speakon NL4C connectors for your output connectors (see Figure 3.5). If your amplifier includes barrier block outputs, you may use spade lugs or bare wire for your output connectors (see Figure 3.6).
CE 4000 Power Amplifier 3 Setup 3.6 Wire Your System 3.6.1 Stereo Mode Typical input and output wiring is shown in Figure 3.8. INPUTS: Connect input wiring for both channels. OUTPUTS: Maintain proper polarity (+/-) on output connectors. Connect Channel-1 positive (+) speaker load to Channel-1 positive terminal of amp; repeat for negative (-). Repeat Channel-2 wiring as for Channel 1. Refer to Section 3.6 for output connector pin assignments.
CE 4000 Power Amplifier 3 Setup 4 Operation 3.7 Connect to AC Mains Connect your amplifier to the AC mains power source (power outlet) with the supplied AC power cordset. First, connect the IEC end of the cordset to the IEC connector on the amplifier; then, plug the other end of the cordset to the AC mains. 4.1 Precautions Your amplifier is protected from internal and external faults, but you should still take the following precautions for optimum performance and safety: 1.
CE 4000 Power Amplifier 4 Operation 4.2 Front Panel Controls and Indicators A. Power Switch Amplifier is on when the switch is in the “I” position. B. Cooling Vents Front-to-rear forced airflow. D. Signal Indicator Green LED illuminates to indicate the presence of signal at the corresponding channel’s input. One per channel. E. Clip Indicator Red LED illuminates when the channel’s output signal is being overdriven. One per channel. C. Power Indicator F.
CE 4000 Power Amplifier 4 Operation 4.3 Back Panel Controls and Connectors H. Balanced Barrier Block Inputs (if equipped) Screw-terminal Barrier Block. One set per channel. K. 5-Way Binding Post Outputs (if equipped) Accept banana plugs, spade lugs or bare wire. (European models do not accept banana plugs). One pair per channel O. Mode Switch Allows selection of Stereo or Bridge operation. L. IEC Power Connector P. Low-Pass Filter Switch Allows selection of Flat, 80 Hz or 100 Hz roll-off.
CE 4000 Power Amplifier 5 Advanced Features and Options 4. NOTE: For detailed information about these Crown amplifier features, please consult the Crown Amplifier Application Guide, available on the Crown website at www.crownaudio.com. 5.1 Protection Systems Your Crown amplifier provides extensive protection and diagnostic capabilities, including built-in anti-clip limiters, amplifier fault protection, and switchable high-pass filters. Figure 5.2 Fault Jack 5.1.
CE 4000 Power Amplifier PFC, however, compensates for phase differences in the power supply, allowing more true power to be transferred to the amplifier. The result is more power with less waste than any other conventional switching or non-switching design. 5.3.2 Neutrik Speakon Wiring The Neutrik Speakon NL4 connector is a fourpole type, which allows either one or two sets of speakers to be wired to one connector. Figure 5.5 shows the wiring pin assignments. 5.4.
CE 4000 Power Amplifier 6 Troubleshooting CONDITION: Normal operation. CONDITION: No sound. POSSIBLE REASON: POSSIBLE REASON: • This is normal operation for your amp. • The amplifier has just been turned on and is still in the 4-second turn-on delay. CONDITION: No power to the amplifier. POSSIBLE REASON: • The amplifier’s “Power” switch is off. • The amplifier is not plugged into the power receptacle. • The amplifier’s high-voltage power supply fuse has blown.
CE 4000 Power Amplifier 7 Specifications Minimum Guaranteed Power (watts) Dual Mode, both channels driven 1 kHz with 0.5% THD 2 ohm (per ch.), ≥ 200-V line voltage 2 ohm (per ch.), < 200-V line voltage 4 ohm (per ch.) 8 ohm (per ch.) 1,800 1,400 1,200 600 Bridge-Mono Mode 1 kHz with 0.5% THD 4 ohm, ≥ 200-V line voltage 4 ohm, < 200-V line voltage 8 ohm 3,600 2,800 2,400 Performance Frequency Response (at 1 watt, 20Hz - 20kHz) ± 0.25 dB (see Figure 7.
CE 4000 Power Amplifier 7 Specifications Required AC Mains 50/60 Hz, 100-240VAC (±10%) AC Line Currentt 100 Volts 120 Volts 230-240 Volts At Idle, amp draws no more than120 watts 8.5 A 7.1 A 3.7 A Construction Ventilation Flow-through ventilation from front to back. Cooling 3-speed fan-on-demand. Dimensions Width Height Depth (behind mounting surface) EIA Standard 19-inch rack mount (EIA RS-310-B); 5.25 inch (13.3 cm) 16.25 inch (36.6 cm) with additional 1-inch (2.
CE 4000 Power Amplifier 8 Service Crown amplifiers are quality units that rarely require servicing. Before returning your unit for servicing, please contact Crown Technical Support to verify the need for servicing. This unit has very sophisticated circuitry which should only be serviced by a fully trained technician. This is one reason why each unit bears the following label: CAUTION: To prevent electric shock, do not remove covers. No user serviceable parts inside.
CE 4000 Power Amplifier 9 Warranty UNITED STATES & CANADA 3 AR YE SUMMARY OF WARRANTY Crown International, 1718 West Mishawaka Road, Elkhart, Indiana 46517-4095 U.S.A. warrants to you, the ORIGINAL PURCHASER and ANY SUBSEQUENT OWNER of each NEW Crown product, for a period of three (3) years from the date of purchase by the original purchaser (the “warranty period”) that the new Crown product is free of defects in materials and workmanship.
CE 4000 Power Amplifier 9 Warranty WORLDWIDE EXCEPT USA & CANADA 3 AR YE page 20 by repair, replacement, or refund. We may not elect refund unless you agree, or unless we are unable to provide replacement, and repair is not practical or cannot be timely made. If a refund is elected, then you must make the defective or malfunctioning product available to us free and clear of all liens or other encumbrances.
CE 4000 Power Amplifier Crown Factory Service Information Shipping Address: Crown Factory Service, 1718 W. Mishawaka Rd.
CE 4000 Power Amplifier THIS PAGE INTENTIONALLY LEFT BLANK page 22 Operation Manual
CE 4000 Power Amplifier NOTES Operation Manual page 23