R.S.V.P. Remote Switching Voltage Provider 120 VAC North American Units Only: © 1998 by Crown International, Inc., P.O. Box 1000, Elkhart, IN 46515-1000 U.S.A. Telephone: 219-294-8000. Fax: 219-294-8329. Trademark Notice: Crown ® is a registered trademark of Crown International, Inc. Other trademarks are the property of their respective owners.
R.S.V.P. Remote Switching Voltage Provider The information furnished in this manual does not include all of the details of design, production, or variations of the equipment. Nor does it cover every possible situation which may arise during installation, operation or maintenance. If you need special assistance beyond the scope of this manual, please contact our Technical Support Group. Crown Audio Division Technical Support Group Plant 2 SW, 1718 W. Mishawaka Rd., Elkhart, Indiana 46515 U.S.A.
R.S.V.P. Remote Switching Voltage Provider Figure 1.1 R.S.V.P. top view Figure 1.2 R.S.V.P. left side view 1 Welcome Thank you for purchasing the Crown R.S.V.P. (Remote Switching Voltage Provider) accessory module, designed for use with Crown’s CT-10 series amplifiers. The R.S.V.P. takes advantage of Crown’s CT-10 series’ soft-start feature, eliminating the need for expensive sequencing equipment or complicated startup routines. Using Crown’s R.S.V.P.
R.S.V.P. Remote Switching Voltage Provider Feature Summary ❏ Takes advantage of CT-10 series’ soft-start feature, eliminating the need for expensive sequencing equipment. ❏ Provides remote power-up/power-down of systems via a simple momentary switch closure. ❏ Optional IQ System control for added security. ❏ Units are individually powered and can be daisy-chained to control a limitless number of amplifiers. ❏ Each unit directly controls up to 21 amplifiers.
R.S.V.P. Remote Switching Voltage Provider Figure 2.1 Left Panel Facilities 2 Facilities A. Enable Light Green LED located on the left side panel that indicates low voltage supply operation. B. On/Com/Off On, common, and off barrier block input located on the left front panel for connection of remote momentary switches. C. Slave/Aux In Port RJ-11 connector located on the left side panel that allows control from an IQ System aux port. Also used for daisy-chaining R.S.V.P. units together. D.
R.S.V.P. Remote Switching Voltage Provider 3 Installation 3.3 Wiring for Amplifiers This section will give the necessary information for installing the R.S.V.P. into your equipment rack. It will also provide ways to incorporate the R.S.V.P. into your system. Please read this section thoroughly, as the R.S.V.P. has special cooling and mounting requirements. Convenient RJ-11 connectors link the R.S.V.P. to the remote CT-10 series amplifiers. Please note that the RJ-11 jacks are polarity sensitive.
R.S.V.P. Remote Switching Voltage Provider Figure 3.2 System Configuration—R.S.V.P.
Figure 3.3 System Configuration—multiple R.S.V.P.s wired in a bus configuration R.S.V.P.
Figure 3.5 System configuration with several R.S.V.P.s in a “star” configuration Figure 3.4 System configuration with several R.S.V.P.s wired in a bus configuration R.S.V.P.
R.S.V.P. Remote Switching Voltage Provider 3.4 Daisy-Chaining Multiple R.S.V.P. Units Together You’ll need standard cable with RJ11 connectors to daisy-chain multiple R.S.V.P. units together. (Refer to Section 3.3 for information on the RJ11 connectors.) To slave R.S.V.P. units, connect one end of the cable from one of the “To Amplifier Remote” ports on the R.S.V.P. unit which will be configured as the master unit.* Connect the other end of the cable to the “Slave/Aux In” port on the remote unit.
R.S.V.P. Remote Switching Voltage Provider 3.6 Wiring for Remote Control using Manual Switching The R.S.V.P. can also be configured to accommodate manual switching. In order to do this, you will need two normally-open momentary switches (available at your local electrical supply store).* One switch will provide the signal to turn the unit on, while the other will provide the signal to turn the unit off.
R.S.V.P. Remote Switching Voltage Provider 4 Operation The R.S.V.P. lets you control the power-up/power-down function of your CT-10 series amplifier from across the room—or across the stadium. Units are individually powered, allowing you to daisy-chain any number of R.S.V.P.s for remote control of an unlimited number of amplifiers. Each R.S.V.P. unit controls 21 amplifier remote jacks. That’s enough to control a 6-foot (1.
R.S.V.P. Remote Switching Voltage Provider 5 Technical Information 6 Specifications Since the R.S.V.P. is used with Crown’s CT-10 series of amplifiers, it is important to note the safety features present at turn-on with the CT-10 amplifiers. Line Voltage Requirements: Dual range power supply operates at 100-120/200-240 V, 50/60 Hz. All CT-10 series amplifiers have a four-second turn-on delay. This prevents dangerous turn-on transients.
R.S.V.P. Remote Switching Voltage Provider 7 Service This unit has very sophisticated circuitry which should only be serviced by a fully trained technician. This is one reason why each unit bears the following label: CAUTION: To prevent electric shock, do not remove covers. No user serviceable parts inside. Refer servicing to a qualified technician. 7.1 Changing the Fuse 1) Disconnect the IEC power cord from the wall. 2) Insert a small, flat blade screwdriver into the pry slot.
R.S.V.P. Remote Switching Voltage Provider 7.2 Worldwide Service 7.3.2 Factory Service Service may be obtained from an authorized service center. (Contact your local Crown/Amcron representative or our office for a list of authorized service centers.) To obtain service, simply present the bill of sale as proof of purchase along with the defective unit to an authorized service center. They will handle the necessary paperwork and repair.
R.S.V.P. Remote Switching Voltage Provider 3. Do not ship the unit in any kind of cabinet (wood or metal). Ignoring this warning may result in extensive damage to the unit and the cabinet. Accessories are not needed—do not send the instruction manual, cables and other hardware. If you have any questions, please call or write the Crown Technical Support Group. Crown Audio Division Technical Support / Factory Service Plant 2 SW, 1718 W. Mishawaka Rd., Elkhart, Indiana 46517 U.S.A.
R.S.V.P. Remote Switching Voltage Provider 3 YEAR NORTH AMERICA SUMMARY OF WARRANTY The Crown Audio Division of Crown International, Inc., 1718 West Mishawaka Road, Elkhart, Indiana 46517-4095 U.S.A. warrants to you, the ORIGINAL PURCHASER and ANY SUBSEQUENT OWNER of each NEW Crown product, for a period of three (3) years from the date of purchase by the original purchaser (the “warranty period”) that the new Crown product is free of defects in materials and workmanship.
R.S.V.P. Remote Switching Voltage Provider 3 WORLDWIDE SUMMARY OF WARRANTY The Crown Audio Division of Crown International, Inc., 1718 West Mishawaka Road, Elkhart, Indiana 46517-4095 U.S.A.
R.S.V.P. Remote Switching Voltage Provider Crown Factory Service Information Shipping Address: Crown International, Inc., Factory Service, Plant 2 SW, 1718 W. Mishawaka Rd., Elkhart, IN U.S.A.