XLS Series XLS 202 Operation Manual XLS 402 XLS 602 Obtaining Other Language Versions: To obtain information in another language about the use of this product, please contact your local Crown Distributor. If you need assistance locating your local distributor, please contact Crown at 574-294-8000. This manual does not include all of the details of design, production, or variations of the equipment. Nor does it cover every possible situation which may arise during installation, operation or maintenance.
XLS Series Power Amplifiers Important Safety Instructions 1) 2) 3) 4) 5) 6) 7) Read these instructions. Keep these instructions. Heed all warnings. Follow all instructions. Do not use this apparatus near water. Clean only with a dry cloth. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus that produce heat.
XLS Series Power Amplifiers Table of Contents Important Safety Instructions ...................................................... 2 4.2 Front Panel Controls and Indicators........................ 9 1 Welcome ...................................................................................... 4 4.3 Back Panel Controls and Connectors .................... 10 1.1 Features......................................................................... 4 5 Advanced Features and Options..........................
XLS Series Power Amplifiers 1 Welcome The XLS Series of power amplifiers from Crown represents a new era in affordable, quality power amplification. The line consists of three models in a uniform, rugged chassis, incorporating the best of tried-andtrue design principles and innovative features. Modern power amplifiers are sophisticated pieces of engineering capable of producing extremely high power levels.
XLS Series Power Amplifiers 3 Setup 3.1 Unpack Your Amplifier 3.3 Mount Your Amplifier 3.4 Ensure Proper Cooling YOU WILL NEED (not supplied): CAUTION: Before you begin, make sure your amplifier is disconnected from the power source, with power switch in the “off” position and all level controls turned completely down (counterclockwise). When using an equipment rack, mount units directly on top of each other. Close any open spaces in rack with blank panels. DO NOT block side or front air vents.
XLS Series Power Amplifiers 3 Setup 3.5 Choose Input Wire and Connectors 3.6 Choose Output Wire and Connectors Crown recommends using pre-built or professionally wired, balanced line (two-conductor plus shield), 22-24 gauge cables and connectors. You should use 3-pin male XLR cable ends at the amplifier inputs. Unbalanced line may also be used but may result in noise over long cable runs.
XLS Series Power Amplifiers 3 Setup 3.7 Wire Your System 3.7.1 Stereo Mode Typical input and output wiring is shown in Figure 3.6. INPUTS: Connect input wiring for both channels. OUTPUTS: Maintain proper polarity (+/-) on output connectors. 3.7.2 Bridge-Mono Mode 120V 110V Connect Channel 1 positive (+) speaker load to Channel 1 positive (red) terminal of amp; repeat for negative (-). Repeat Channel 2 wiring as for Channel 1. Figure 3.6.
XLS Series Power Amplifiers 3 Setup 4 Operation 3.8 Connect to AC Mains Connect your amplifier to the AC mains power source (power outlet) with the supplied AC power cordset. First, connect the IEC end of the cordset to the IEC connector on the amplifier; then, plug the other end of the cordset to the AC mains. 4.1 Precautions Your XLS Series amplifier is protected from internal and external faults, but you should still take the following precautions for optimum performance and safety: 1.
XLS Series Power Amplifiers 4 Operation A. Cooling Vents Front-to-rear forced airflow. C. Clip Indicators Two red LEDs, one for each channel, illuminate when the channel’s output signal is being overdriven. B. Level Controls Two black rotary level controls, one for each channel. D. Power Indicator Green LED indicates amplifier has been turned on and AC power is available. 4.2 Front Panel Controls and Indicators E. Fault Indicator Yellow LED illuminates when amplifier is in protect mode.
XLS Series Power Amplifiers 4 Operation 4.3 Back Panel Controls and Connectors G. Power Connector H. Fuse Provides overload protection. I. Voltage Selector Two-position switch is factory-set to country-specific voltage. WARNING: Do not operate your amplifier with an incorrect voltage selected or amplifier damage may result. J. Male XLR Signal Links One per channel; male XLR connectors are provided for daisy-chaining to other amplifiers. M.
XLS Series Power Amplifiers 5 Advanced Features and Options NOTE: For detailed information about these Crown amplifier features, please consult the Crown Amplifier Application Guide, available on the Crown website at www.crownaudio.com. 5.
XLS Series Power Amplifiers 6 Troubleshooting CONDITION: No sound. CONDITION: Normal operation. POSSIBLE REASON: POSSIBLE REASON: • This is normal operation for your amp. CONDITION: No power to the amplifier. POSSIBLE REASON: • The amplifier’s “power” switch is off. • The amplifier is not plugged into the power receptacle. • The amplifier’s high-voltage power supply fuse has blown. Refer to the Advanced Features and Options section of this manual for instruction on fuse replacement.
XLS Series Power Amplifiers 7 Specifications Minimum Guaranteed Power (watts) XLS202 XLS402 XLS602 Stereo, 2 ohm (per ch.) 250 570 840 Stereo, 4 ohm (per ch.) 200 400 600 Stereo, 8 ohm (per ch.) 145 260 370 Stereo, 2 ohm (per ch.) 260 610 880 Stereo, 4 ohm (per ch.) 225 445 670 Stereo, 8 ohm (per ch.) 155 275 400 120 VAC, 60 Hz Units, per channel, both channels driven 1 kHz with 0.1% THD 240 VAC, 50 Hz Units, per channel, both channels driven 1 kHz with 0.
XLS Series Power Amplifiers 7 Specifications Construction All Models Ventilation Cooling Air Volume Requirements (per minute per unit) Dimensions Width Height Depth (behind mounting surface) Weight Net Weight Shipping Weight page 14 Flow-through ventilation from front to back. Internal heat sinks with forced-air cooling for rapid, uniform heat dissipation. 80.15 ft³ (2.27 m³) EIA Standard 19-inch rack mount (EIA RS-310-B); 5.25 inch (13.3 cm) 12.6 inch (32.0 cm). XLS202 30 lbs. (13.6 kg) 37 lbs. (16.
XLS Series Power Amplifiers 8 Service Crown amplifiers are quality units that rarely require servicing. Before returning your unit for servicing, please contact Crown Technical Support to verify the need for servicing. This unit has very sophisticated circuitry which should only be serviced by a fully trained technician. This is one reason why each unit bears the following label: CAUTION: To prevent electric shock, do not remove covers. No user serviceable parts inside.
XLS Series Power Amplifiers 9 Warranty UNITED STATES & CANADA 3 AR YE SUMMARY OF WARRANTY Crown International, 1718 West Mishawaka Road, Elkhart, Indiana 46517-4095 U.S.A. warrants to you, the ORIGINAL PURCHASER and ANY SUBSEQUENT OWNER of each NEW Crown product, for a period of three (3) years from the date of purchase by the original purchaser (the “warranty period”) that the new Crown product is free of defects in materials and workmanship.
XLS Series Power Amplifiers 9 Warranty WORLDWIDE EXCEPT USA & CANADA 3 AR YE SUMMARY OF WARRANTY Crown International, 1718 West Mishawaka Road, Elkhart, Indiana 46517-4095 U.S.A.
XLS Series Power Amplifiers Notes page 18 Operation Manual
XLS Series Power Amplifiers Crown Factory Service Information Shipping Address: Crown International, Factory Service, Plant 2 SW, 1718 W. Mishawaka Rd.