Operation Manual Power Amplifier Xs Series

Operation Manual
Xs Series Power Amplifiers
page 16
Minimum Guaranteed Power Xs500 Xs700 Xs900 Xs1200
120 VAC, 60 Hz Units, per channel, both channels driven
1 kHz with 0.15% THD
Dual, 2 ohms (per ch.) 750W* 900W* 1200W* 1600W*
Dual, 4 ohms (per ch.) 500W 750W 900W 1100W
Dual, 8 ohms (per ch.) 400W 450W 600W 650W
Bridge mono, 4 ohms 1600W* 1900W* 2500W* 3000W*
Bridge mono, 8 ohms 1450W 1645W 2100W 2300W
Performance Xs500 Xs700 Xs900 Xs1200
Sensitivity (volts RMS) for full rated power at 4 ohms 1.4V 1.4V 1.4V 1.4V
Frequency Response (at 1 watt, 22Hz - 22 kHz) ± 1 dB ± 1 dB ± 1 dB ± 1 dB
Phase Response (at 1 watt, 20Hz to 20 kHz) +5°, –18° +5°, –18° +5°, –18° +5°, –18°
Signal to Noise Ratio below rated power (typical)
A-weighted
22 Hz to 22 kHz filter
> 102 dB
> 97 dB
> 103 dB
> 98 dB
> 108 dB
> 106 dB
> 109 dB
> 107dB
Total Harmonic Distortion (THD) at 1 full bandwidth power, from 20
Hz to 20 kHz
< 0.5% < 0.5% < 0.5% < 0.5%
Intermodulation Distortion (IMD) 60 Hz and 7 kHz at 4:1,
from full rated output to –30 dB
from full rated output to –40 dB
< 0.5%
< 1.0%
< 0.5%
< 1.0%
< 0.5%
< 1.0%
< 0.5%
< 1.0%
6 Specifications
OUTPUT ASSIGNMENT
PIN CH PIN CH
1+ 2 1+ 1
1– 2 1– 1
2+ NC 2+ 2
2– NC 2– 2
CH 2 CH 1
* at 0.5% THD.