TABLE 11.1a: BECKETT BURNER CONFIGURATION AND SETUP DATA
BOILER MODEL FWZ060 FWZ080 FWZ100 FWZ130 FWZ160
BURNER MODEL AFG AFG AFG AFG AFG
AIR TUBE COMBO 70MQASN 70MMAQN 70MMAQN 70MLASN 70MLASN
HEAD TYPE L2 L1 L1 V1 V1
STATIC PLATE 3-3/8U 3-3/8U 3-3/8U NONE 2-3/4M
LOW FIRING RATE BAFFLE
BECKETT
SILVER (5880)
BECKETT
SILVER (5880)
NONE NONE NONE
INSERTION LENGTH 2.0 2.0 2.0 2.0 2.0
PITCH ANGLE 0 0 0 0 0
STANDARD NOZZLE
DELAVAN
.50 X 45W
DELAVAN
.65 X 60A
DELAVAN
.85 X 60B
HAGO
1.10 X 60B
HAGO
1.35 X 60B
PUMP PRESSURE (psi) 180 150 150 150 150
HEAD SETTING FIXED FIXED FIXED 0.0 3.0
STARTING:
SHUTTER SETTING
BAND SETTING
8
0
10
1
7
1
8
2
9
5
DRAFT IN FLUE (in w.c.) 0 to -0.02 0 to -0.02 0 to -0.02 0 to -0.02 0 to -0.02
MAX SMOKE
(Bacharach Scale)
#1 #1 #1 #1 #1
FLUE CO
2
(%)
MIN.
MAX.
11.5
12.8
11.5
12.8
11.5
12.8
11.5
12.8
11.5
12.8
WARNING
Attempts to use burners or burner configurations other than those shown in Table 11.1 could
result in reliability problems, property damage, personal injury or loss of life
TABLE 11.1b: RIELLO BURNER CONFIGURATION AND SETUP DATA
BOILER MODEL FWZ060 FWZ080 FWZ100 FWZ130 FWZ160
BURNER MODEL F3 F3 F5 F5 F5
TURBULATOR DISK 5 SLOT 5 SLOT 9 SLOT 9 SLOT 9 SLOT
COMBUSTION HEAD VSBT VSBT 10” LBT 6” SBT VSBT
STANDARD NOZZLE
DELAVAN
.50 X 70W
DELAVAN
.65 X 70A
DELAVAN
.85 X 60B
DELAVAN
1.10 X 60B
DELAVAN
1.35 X 60B
INSERTION LENGTH 2.25 2.25 10 3.5 2.25
PUMP PRESSURE (psi) 145 145 145 150 145
TURBULATOR SETTING 1.0 3.0 2.0 4.0 4.0
AIR GATE SETTING 2.25 2.75 2.5 3.75 4.0
DRAFT IN FLUE (in w.c.) 0 to -0.02 0 to -0.02 0 to -0.02 0 to -0.02 0 to -0.02
MAX SMOKE
(Bacharach Scale)
#1 #1 #1 #1 #1
FLUE CO
2
(%)
MIN.
MAX.
11.5
12.8
11.5
12.8
11.5
12.8
11.5
12.8
11.5
12.8