Owners Manual

Page 28 of 66
The gas supply hose portion must be readily visible across its entire length for
inspection. Removal or opening of an access plate(s) or door(s) without the use of tools
for inspection purposes is considered acceptable.
A gas appliance pressure regulator shall be installed in a location so that it will not
attain a temperature in excess of that specified by the regulator manufacturer as
determined during conduct of Clause 5.14, Wall, floor, and component temperatures,
or Clause 5.21.5, as applicable per Standard ANSI Z83.11/CSA 1.8. On a built-in unit,
the gas appliance pressure regulator shall be installed in a location where pressure
adjustments can be made from the front when the appliance is in a normally installed
position.
The vent of any fuel cylinder regulator must be protected from adverse weather.
The regulator used on the self-contained LP-gas supply system shall be in a location
such that it will not attain a temperature above 140°F (60 °C) when tested in
accordance with Clause 5.14, Wall, floor, and component temperatures
per Standard
ANSI Z83.11/CSA 1.8.
NATURAL GAS REQUIREMENTS
Verify the type of gas your grill/side burner has been configured for by the factory by
checking the rating plate on the appliance (See Appendix “A” for further details).
Grills
and side burners configured for natural gas (NG) are orificed differently than units
configured for liquid propane (LP) gas. Appliances configured for use with natural gas
are shipped with a regulator fitted with a 3/4 inch flare fitting for the inlet connection.
For the mobile, Non-Modular Grill models, IE30, IE36,IE42 and IE36I, the regulator is
positioned inside the cabinet on the right hand back rear corner. The grills are
equipped with a with a 10 foot hose, regulator and quick-connect fitting
(See “Figure 8” for installation details).
For fixed modular grill and side burner models, IGM24, IGM36, IGM42 and ICM-SB, the
regulator is positioned inside the cabinet on the right hand back rear corner. The
regulator is fitted with a 3/4 inch male flare fitting and the certified gas installer will
connect the gas supply at this fitting (See “Figure 8” for installation details).
For Built-In grills and side burners, the regulator is provided separately. The appliances
are equipped with a 1/2 O.D. corrugated gas line with a 3/4 inch female flare fitting.
The connection to the regulator and gas supply must be done in accordance with this
manual and completed by a certified gas technician (See “Figure 9” for further details).