Product Specifications

Crown Battery Manufacturing’s team of product and application experts
welcome the opportunity to discuss your technical requirements during
the design and specification stage. To access this support, please contact:
BCI
Group
Size
Model
Description
Nominal
Voltage
Length Width
Container
Height
Terminal
Height
Weight
Cover &
Container
Material
Case to Cover
Seal Method
in mm in mm in mm in mm lbs kgs
2CRV1200 2 11.62 295 7.0 1 178 15.91 404 16.10 409 130 59.1 ABS Heat Seal
1445 Majestic Drive | P.O. Box 990 | Fremont, OH USA | 419.334.7181 | Fax 419.334.7124 | www.crownbattery.com
Power. Sheet.
2CRV1200
AGM Deep Cycle
THE POWER OF 1
VRLA AGM | Non-Spillable | Maintenance-Free
AVAILABLE
TERMINAL
STYLE
Ampere Hour Capacity (Ah) Discharge Capacity Minutes KWH (kWh) Int Res. Short Circuit Current
CCA CA 100 Hr 20 Hr 5 Hr 75A 25A 20A 15A 5A 100 Hr 80°F / 27°C Amperes
1660 1200 862 800 3300 4300 6000 25000 3.22 0.20mΩ 8400
ELECTRICAL SPECIFICATIONS
PHYSICAL SPECIFICATIONS
State of Charge Percentage 100% 75% 50% 25% 0%
Open Circuit Voltage - Cell 2.14 2.09 2.04 1.99 1.94
AGM BATTERY STATE OF CHARGE MEASUREMENT
Operating Temperature Range Self Discharge
Terminal & Torque Specications
Best Practices
Maximum Limit -4°F to 120°F
(-20°C to 49°C) with proper temperature
compensation controls. Lead acid
batteries are temperature sensitive: refer
to the temperature / capacity projection
chart to identify available capacity at the
application operating temperature.
Application Note: Maintain a state
of charge greater than 60% when
operating batteries at temperatures
below 3F (0°C).
Approximately 3%
per month at 8F
(27°C). Rate of
self discharge will
vary depending
on storage
temperature.
Freshening charge
recommended for
inventory at
75% SOC voltage.
Battery terminal connections
should be secured and tight at
all times. Replace torn or
damaged cabling or connectors.
62-88 in-lbs / 7 to 10 Nm
Safety is Your Responsibility!
Keep sparks, flames and cigarettes away
from batteries at all times. Maintain good ventilation when working on or
charging batteries. Do not install or charge batteries in a sealed compartment.
Keep batteries and terminal connections clean, dry and free of dirt and
corrosion. Do not tamper with vent structures.
Optimize the life of your batteries by limiting duty cycle depth of discharge
to 75% or less.
Charging service must be performed with equipment configured to support
the charging recommendations herein. Opportunity charging service can
be performed when batteries are no more than 50% discharged. Batteries
must be fully recharged after the termination of duty cycle usage. Chronic
under-charge or over-charge will shorten battery life.
APPLICATION NOTES
Crown Battery Manufacturing’s
Product Support Department
+
1.419.334.7181 / Fax
+
1.419.334.7124
commercial@crownbattery.com

Summary of content (2 pages)