User`s manual

3–2
FM2000A User’s Manual
These steps summarize the operating procedures you should use for the initial
operation of the power amplifier and power supply of the FM2000A.
1. Ensure that the external remote control unit is properly connected (See
Section 2.6 and the pin-out description table on page 2–8 for proper pin
configuration). If not using a remote control unit, pin 7 must be tied to
ground pin 6.
2. Connect Antenna.
3. If using an external remote control, enable the power supply via the remote
I/O connector.
4. Turn on (set to up) the AC input circuit breaker located on the rear panel of
the power supply (do not turn on the front panel power switch yet).
3.1 Initial Power-up Procedures
5. Turn on the exciter (a Crown FM100 or equivalent) and adjust its RF power
output level until the In Reference (In Ref) voltage, as indicated on the PA2000
front panel Digital Multimeter, is between 0.8 and 1.2 volts. This is not a drive
dependent amplifier; therefore drive must be at a constant level regardless of
main output power.
Note: The unit will not operate until the exciter is active
and produces sufficient drive.
Illustration 3–1 PS2000 Back Panel Functions
240 VAC IN
AC Input
Circuit Breaker
Outputs to
PA1000
Air Exhaust Vents
+ DC Output
DC Output
PS2000
Fans
Power
Control
OFF
OFF
Fan
Circuit Breaker