Specifications

2–9
Installation
Severe shock hazard!
Do not touch the inner
portion of the RF
output connector
when transmitter
power is on.
WARNING
Illustration 2–10 RF Connections
2.6 RF Connections
Connect the RF load, an antenna or the input of an external power amplifier, to
the type-N, RF output connector on the rear panel. VSWR should be 1.5:1 or
better.
The RF monitor is intended primarily for a modulation monitor connection.
Information gained through this connection can supplement that which is
available on the transmitter front panel displays.
If your transmitter is equipped with the receiver option, connect the incoming RF
to the RF IN connector.
115V
RF Output
Connector
RF Output
Monitor
RFInput Connector
(receiver option only)