User`s manual
Crown Broadcast FME 350W to 2000W User Manual– 05/2013
Page 18
Crown Broadcast, a division of International Radio & Electronics Corporation 25166 Leer Drive, Elkhart, Indiana, 46514-5425 USA
Ph +1 (574) 262 8900
3.5. AF inputs
Analog (LINE1)
Connector "XLR" type
Impedance > 10 kΩ by default, adjustable to 600 Ω by jumpers, balanced
Bandwidth Software adjustable
Level Software adjustable (-18/+18 dBu range)
AES (LINE2)
Connector "XLR" type
Impedance > 110 Ω balanced
Bandwidth Software adjustable
Level Software adjustable (-20 to 0 dBFS range)
Sampling rate Auto adjusted up to 192 kHz
Bit 16, 24, 32
Multiplex (MPX/SCA)
Connector "BNC" type
Impedance > 5 kΩ unbalanced
Level Software adjustable (-18/+18 dBu range)
3.6. HF output
Connector 7/16 type
Impedance 50 Ω
Monitoring (RF Monitor)
Level
Crown Broadcast FME 350 W / 750 W / 1000 W 10 dBm 3 dB @ 750 W at main output
Crown Broadcast FME 1500 W / 2000 W 10 dBm 3 dB @ 1500 W at main output
Slope 20 x Log (F/98)
Directivity >20 dB in the band
3.7. Power supply
Voltage 184 VAC to 264 VAC
Frequency 47 Hz - 63 Hz
Max consumption 550 W @ nominal power (350 W version)
1150 W @ nominal power (750 W version)
1550 W @ nominal power (1000 W version)
2300 W @ nominal power (1500 W version)
3050 W @ nominal power (2000 W version)
Fuses (for Crown Broadcast FME 350 W / 750W / 1000 W) 10 AT