3.1. Interface panel
Indicators Green CPU LED: CPU activity
Red FAULT LED: major fault
Yellow WARNING LED: minor fault
Red RF (3 dB) LED: RF fault (3 dB)
Red VSWR LED: VSWR fault
Green INTERLOCK LED: safety interlock
Green RF LED: RF on
Orange LOCAL LED: local mode
Screens Back lighted LCD: displays operating parameters and menus.
Buttons RF, local, +, -- and OK
3.2. Environmental
Nominal operating temperature 5°C to 45°C
Maximum operating temperature 0°C to 50°C
Warehousing temperature -20°C to +70°C
Warehousing time < 10 years
Cooling Internal ventilation
Crown Broadcast FME 350 W: ~20 I/s
Crown Broadcast FME 750 W: ~20 I/s
Crown Broadcast FME 1000 W: ~20 I/s
Crown Broadcast FME 1500 W: ~55 l/s
Crown Broadcast FME 2000 W: ~55 l/s
3.3. Physical
Crown Broadcast FME 350 W / 750 W / 1000 W
Overall dimension 19’’ (482.6 mm) X 3U (133.5 mm) X 470 mm
Rack size without front panel 440.4 X 126.2 X 432 mm (WxHxD)
Enclosure depth required 600 mm
Mounting 19’’enclosure, with 4 M6X12 screws
Weight around 13 kg
Crown Broadcast FME 1500 W / 2000 W
Overall dimension 19’’ (482.6 mm) X 3U (133.5 mm) X 690 mm
Rack size without front panel 440.4 X 126.2 X 620 mm (WxHxD)
Enclosure depth required 700 mm
Mounting 19’’enclosure, with 4 M6X12 screws
Weight around 18 kg